欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-063L 参数 Datasheet PDF下载

HCPL-063L图片预览
型号: HCPL-063L
PDF下载: 下载PDF文件 查看货源
内容描述: 高速LVTTL兼容3.3伏光电耦合器 [High Speed LVTTL Compatible 3.3 Volt Optocouplers]
分类和应用: 光电输出元件
文件页数/大小: 14 页 / 188 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号HCPL-063L的Datasheet PDF文件第1页浏览型号HCPL-063L的Datasheet PDF文件第2页浏览型号HCPL-063L的Datasheet PDF文件第3页浏览型号HCPL-063L的Datasheet PDF文件第4页浏览型号HCPL-063L的Datasheet PDF文件第6页浏览型号HCPL-063L的Datasheet PDF文件第7页浏览型号HCPL-063L的Datasheet PDF文件第8页浏览型号HCPL-063L的Datasheet PDF文件第9页  
Insulation and Safety Related Specifications
8-Pin DIP
(300 Mil)
Value
7.1
7.4
0.08
SO-8
Value
4.9
4.8
0.08
Parameter
Minimum External Air
Gap (External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Symbol
L (101)
L (102)
Units
mm
mm
mm
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
NA
CTI
200
NA
200
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
IIIa
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
VDE 0884 Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
300 V rms
for rated mains voltage
450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample Test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Characteristic
I-IV
I-III
55/85/21
2
630
1181
Units
V
IORM
V
PR
V
peak
V
peak
V
PR
V
IOTM
945
6000
V
peak
V
peak
T
S
I
S,INPUT
P
S,OUTPUT
R
S
175
230
600
10
9
˚C
mA
mW
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section (VDE 0884), for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
6 − 108