Insulation and Safety Related Specifications  
Value  
Symbol 772X  
Parameter  
072X  
Units  
Conditions  
Minimum External Air  
Gap (Clearance)  
L(I01)  
7.1  
4.9  
mm  
Measured from input terminals to output  
terminals, shortest distance through air.  
Minimum External  
Tracking (Creepage)  
L(I02)  
7.4  
4.8  
mm  
mm  
Measured from input terminals to output  
terminals, shortest distance path along body.  
Minimum Internal Plastic  
Gap (Internal Clearance)  
0.08  
0.08  
Insulation thickness between emitter and  
detector; also known as distance through  
insulation.  
Tracking Resistance  
(Comparative Tracking  
Index)  
CTI  
175  
175  
Volts  
DIN IEC 112/ VDE 0303 Part 1  
Isolation Group  
IIIa  
IIIa  
Material Group (DIN VDE 0110, 1/ 89,  
Table 1)  
board, minimum creepage and  
There are recommended  
All Agilent data sheets report the  
creepage and clearance inherent  
to the optocoupler component  
itself. These dimensions are  
needed as a starting point for the  
equipment designer when  
determining the circuit insulation  
requirements. However, once  
mounted on a printed circuit  
clearance requirements must be  
met as specified for individual  
equipment standards. For  
creepage, the shortest distance  
path along the surface of a  
printed circuit board between the  
solder fillets of the input and  
output leads must be considered.  
techniques such as grooves and  
ribs which may be used on a  
printed circuit board to achieve  
desired creepage and clearances.  
Creepage and clearance distances  
will also change depending on  
factors such as pollution degree  
and insulation level.  