IEC/ EN/ DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
HCPL-772X
Option 060
HCPL-072X
Option 060
Description
Symbol
Units
Installation classification per DIN VDE 0110/ 1.89, Table 1
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/ 1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b†
I-IV
I-IV
I-III
55/ 85/ 21
2
630
I-IV
I-III
55/ 85/ 21
2
560
V
V
PR
Vpeak
Vpeak
IORM
1181
1050
V
IORM
x 1.875 = V , 100% Production
PR
Test with t = 1 sec, Partial Discharge < 5 pC
m
Input to Output Test Voltage, Method a†
V
945
840
Vpeak
Vpeak
PR
V
IORM
x 1.5 = V , Type and Sample Test,
PR
t = 60 sec, Partial Discharge < 5 pC
m
Highest Allowable Overvoltage†
V
IOTM
6000
4000
(Transient Overvoltage, t = 10 sec)
ini
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature
Input Current
Output Power
T
175
230
600
150
150
600
°C
S
I
mA
mW
Ω
S,INPUT
P
S,OUTPUT
R
IO
9
9
Insulation Resistance at T , V = 500 V
≥10
≥10
S
10
† Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
IEC/ EN/ DIN EN 60747-5-2, for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter
Symbol
TS
Min.
–55
–40
0
Max.
125
+85
6.0
Units
°C
Figure
Storage Temperature
Ambient Operating Temperature[1]
Supply Voltages
TA
°C
V
DD1, V
Volts
Volts
Volts
mA
DD2
Input Voltage
V
I
–0.5
–0.5
V
DD1 +0.5
DD2 +0.5
10
Output Voltage
V
O
V
Average Output Current
Lead Solder Temperature
Solder Reflow Temperature Profile
IO
260°C for 10 sec., 1.6 mm below seating plane
See Solder Reflow Temperature Profile Section
Recommended Operating Conditions
Parameter
Symbol
Min.
–40
4.5
Max.
+85
5.5
Units
°C
V
Figure
Ambient Operating Temperature
Supply Voltages
TA
V
DD1, V
DD2
Logic High Input Voltage
Logic Low Input Voltage
Input Signal Rise and Fall Times
V
2.0
V
V
1, 2
IH
DD1
V
IL
0.0
0.8
1.0
V
tr, tf
ms
6