IEC/ EN/ DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)  
HCPL-772X  
Option 060  
HCPL-072X  
Option 060  
Description  
Symbol  
Units  
Installation classification per DIN VDE 0110/ 1.89, Table 1  
for rated mains voltage 150 V rms  
for rated mains voltage 300 V rms  
for rated mains voltage 450 V rms  
Climatic Classification  
Pollution Degree (DIN VDE 0110/ 1.89)  
Maximum Working Insulation Voltage  
Input to Output Test Voltage, Method b†  
I-IV  
I-IV  
I-III  
55/ 85/ 21  
2
630  
I-IV  
I-III  
55/ 85/ 21  
2
560  
V
V
PR  
Vpeak  
Vpeak  
IORM  
1181  
1050  
V
IORM  
x 1.875 = V , 100% Production  
PR  
Test with t = 1 sec, Partial Discharge < 5 pC  
m
Input to Output Test Voltage, Method a†  
V
945  
840  
Vpeak  
Vpeak  
PR  
V
IORM  
x 1.5 = V , Type and Sample Test,  
PR  
t = 60 sec, Partial Discharge < 5 pC  
m
Highest Allowable Overvoltage†  
V
IOTM  
6000  
4000  
(Transient Overvoltage, t = 10 sec)  
ini  
Safety Limiting Values  
(Maximum values allowed in the event of a failure,  
also see Thermal Derating curve, Figure 11.)  
Case Temperature  
Input Current  
Output Power  
T
175  
230  
600  
150  
150  
600  
°C  
S
I
mA  
mW  
S,INPUT  
P
S,OUTPUT  
R
IO  
9
9
Insulation Resistance at T , V = 500 V  
10  
10  
S
10  
Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section  
IEC/ EN/ DIN EN 60747-5-2, for a detailed description.  
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured  
by means of protective circuits.  
Note: The surface mount classification is Class A in accordance with CECC 00802.  
Absolute Maximum Ratings  
Parameter  
Symbol  
TS  
Min.  
–55  
–40  
0
Max.  
125  
+85  
6.0  
Units  
°C  
Figure  
Storage Temperature  
Ambient Operating Temperature[1]  
Supply Voltages  
TA  
°C  
V
DD1, V  
Volts  
Volts  
Volts  
mA  
DD2  
Input Voltage  
V
I
–0.5  
–0.5  
V
DD1 +0.5  
DD2 +0.5  
10  
Output Voltage  
V
O
V
Average Output Current  
Lead Solder Temperature  
Solder Reflow Temperature Profile  
IO  
260°C for 10 sec., 1.6 mm below seating plane  
See Solder Reflow Temperature Profile Section  
Recommended Operating Conditions  
Parameter  
Symbol  
Min.  
–40  
4.5  
Max.  
+85  
5.5  
Units  
°C  
V
Figure  
Ambient Operating Temperature  
Supply Voltages  
TA  
V
DD1, V  
DD2  
Logic High Input Voltage  
Logic Low Input Voltage  
Input Signal Rise and Fall Times  
V
2.0  
V
V
1, 2  
IH  
DD1  
V
IL  
0.0  
0.8  
1.0  
V
tr, tf  
ms  
6