Solder Reflow Thermal Profile
300
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
2.5°C ± 0.5°C/SEC.
160°C
150°C
140°C
3°C + 1°C/–0.5°C
30
SEC.
30
SEC.
SOLDERING
TIME
200°C
Regulatory Information
The HCPL-x710 have been
approved by the following
organizations:
UL
Recognized under UL 1577,
component recognition program,
File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01.
(Option 060 only)
TEMPERATURE (°C)
200
100
PREHEATING TIME
150°C, 90 + 30 SEC.
50 SEC.
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
0
0
50
100
150
200
250
TIME (SECONDS)
Recommended Pb-Free IR Profile
t
p
T
p
T
L
TEMPERATURE
T
smax
T
smin
t
s
PREHEAT
60 to 180 SEC.
25
t 25 °C to PEAK
TIME
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C
t
L
60 to 150 SEC.
260 +0/-5 °C
217 °C
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
RAMP-DOWN
6 °C/SEC. MAX.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
20-40 SEC.
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap (Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
CTI
Symbol
L(I01)
L(I02)
Value
7710
0710
7.1
4.9
7.4
4.8
Units
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along
body.
Insulation thickness between emitter and
detector; also known as distance through
insulation.
DIN IEC 112/VDE 0303 Part 1
0.08
≥175
0.08
≥175
mm
Volts
IIIa
IIIa
Material Group (DIN VDE 0110, 1/89,
Table 1)
There are recommended
techniques such as grooves and
ribs which may be used on a
printed circuit board to achieve
desired creepage and clearances.
Creepage and clearance distances
will also change depending on
factors such as pollution degree
and insulation level.
All Agilent data sheets report the
creepage and clearance inherent
to the optocoupler component
itself. These dimensions are
needed as a starting point for the
equipment designer when
determining the circuit insulation
requirements. However, once
mounted on a printed circuit
4
board, minimum creepage and
clearance requirements must be
met as specified for individual
equipment standards. For
creepage, the shortest distance
path along the surface of a
printed circuit board between the
solder fillets of the input and
output leads must be considered.