Setting the Operating Data Rate Range  
The HDMP-1032A/1034A chipset  
can operate from 260 MBaud to  
1400 MBaud. It is divided into  
three operating data ranges with  
each range selected by setting  
DIV1/0 as shown in the Typical  
Operating Rates table. Two  
is unique. The user serial data  
rate is calculated as:  
setting of DIV1/0 = (0/1) gives  
an upper rate of 45 MHz while a  
setting of DIV1/0 = (0/0) gives a  
lower rate of 40 MHz. The upper  
and lower data rates stated in the  
tables are typical values unless  
indicated by (min) or (max) and  
may vary between individual parts.  
However, each transmitter/receiver  
has overlapping ranges of opera-  
tion providing continuous band  
coverage from 260 to 1400 MBaud.  
Serial Data Rate =  
60MW  
sec  
16bits  
Word  
(–––––) (–––––) =  
960 MBits/sec  
The baud rate includes an addi-  
tional four encoding bits (20 bits  
total) that the HDMP-1032A/34A  
G-Link chipset transmits. The  
serial baud rate is calculated as:  
examples have been provided in  
order to help in understanding  
and using this table.  
Example 1 (Unique Range)  
Serial Baud Rate =  
It is desired to transmit a 16 bit  
parallel word operating at a fre-  
quency of 60 MHz (60 MWord/  
sec). Both the Tx and Rx must  
be set to a range that covers this  
word rate. According to the table  
only a setting of DIV1/0 = (0/0)  
allows a parallel input word rate  
of 40 to 70 MHz. This range  
In this example, each transmitter/  
receiver will permit a 42.5 MHz  
parallel data rate but it is sug-  
gested that DIV0 be tied to a  
jumper that can be set either to  
logic 1(open allowing DIV0 to  
float high) or logic 0(ground).  
This allows the design to accom-  
modate both ranges for maximum  
flexibility. This technique is rec-  
ommended whenever operating  
near the upper and lower ends of  
two adjacent word rate ranges.  
60MW  
20bits  
(–––––) (–––––) =  
sec  
Word  
1200 MBaud  
Example 2 (Overlapping Ranges)  
Some applications may have a  
parallel word rate that seems  
to fit in two ranges of opera-  
tion. For example, a 42.5 MHz  
(42.5 MWord/s) parallel data  
rate falls within two ranges:  
DIV1/0 = (0/0) and DIV1/0 =  
(0/1). According to the table, a  
setting easily accommodates the  
required 60 MHz word rate and  
HDMP-1032A (Tx), HDMP-1034A (Rx)  
1,2  
Typical Operating Rates  
Tc = 20°C to +85°C, V = 3.15V to 3.45V  
CC  
Parallel Word Rate  
(MWord/sec)  
Serial Data Rate  
Serial Baud Rate  
(MBaud)  
(MBits/sec)  
Range  
640  
DIV1  
DIV0  
Range  
Range  
0
0
1
0
1
0
40  
20  
70 (max)  
45  
1120 (max)  
720  
800  
400  
1400 (max)  
900  
320  
13 (min) 26  
208 (min) 416  
260 (min) 520  
WORD RATE (MWords/sec)  
50  
5
25  
75  
100  
800  
1400 (MAX.)  
0/0  
0/1  
900  
400  
1/0  
260 (MIN.)  
100  
520  
500  
1000  
SERIAL BAUD RATE (MBaud)  
1500  
2000  
1
Figure 2. Typical data rates showing ranges of operation .  
Notes:  
1. All values in this table and graph are typical unless otherwise noted by (min) or (max), (min) indicates a minimum guaranteed value,  
(max) indicates a maximum guaranteed value.  
2. All values in this table are expected for a BER less than 10  
-14  
.