AWT6123
ELECTRICAL CHARACTERISTICS
Table 1: Absolute Maximum Ratings
PARAMETER
Supply Voltage (V
CC
)
RF Input Power (RF
IN
)
Control Voltage (V
APC
)
Storage T
emperature (T
STG
)
MIN
MAX
+7
+14
3.0
UNITS
V
dBm
V
°C
-55
150
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure to
absolute ratings for extended periods of time may adversely affect
reliability.
Table 2: ESD Ratings
PARAMETER
ESD threshold voltage (RF ports)
ESD threshold voltage (control inputs)
ESD threshold voltage (RF inputs)
ESD threshold voltage (control inputs)
METHOD
HBM
HBM
CDM
CDM
RATING
250
250
TBD
TBD
UNITS
V
V
V
V
Table 3: Operating Conditions
PARAMETER
Supply voltage (V
CC
)
Regulated voltage (V
REG
)
Individual Regulated current (I
REG
)
Control voltage (V
APC
)
Control Voltage (V
APC
) for max power
CONDITIONS
MIN
3.0
2.7
TYP
3.5
2.8
3.5
MAX
4.2
3.0
4.5
V
REG
UNITS
V
V
mA
V
V
mA
V
REG_GSM
or V
REG_DCS/PCS
= 3.0V
0.45
1.8
V
APC
= 0.45V
-3
2.2
Individual Control current (I
APC
)
See Note 1
V
APC
= 2.2V
V
APC
= 3.0V
3
6
0
-20
10
85
mA
mA
Leakage current
V
CC
= 4.2V, No RF Applied
V
REG_GSM
= V
REG_DCS/PCS
= 0V
µ
A
Case temperature (T
C
)
°C
Note 1: The V
APC
must be pulled down to 0.45V with a low impedance. If V
REG_GSM
& V
REG_DCS/PCS
inputs
are connected then both V
APC
inputs must be pulled down to 0.45V to disable both power amplifiers.
2
Advanced Product Information - Rev 0.7
02-2003