Electrical Specifications (DC)
Over recommended temperature (T
A
= 0°C to 70°C) unless otherwise specified. See note 9.
Parameter
Current
Transfer
Ratio
Sym.
CTR
Device
HCPL-2530/
0530
Min.
7
5
Typ.*
18
Max.
50
Units
%
Test Conditions
T
A
= 25°C
I
F
= 16 mA,
V
CC
= 4.5 V
V
O
= 0.5 V
Fig.
1, 2
4
Note
1, 2
HCPL-2531/
0531
HCPL-4534/
0534
Logic Low
Output
Voltage
V
OL
HCPL-2530/
0530
19
15
24
50
%
T
A
= 25°C
0.1
0.5
0.5
V
T
A
= 25°C
I
O
= 1.1 mA
I
O
= 0.8 mA
I
F
= 16 mA,
V
CC
= 4.5 V
1
1
HCPL-2531/
0531
HCPL-4534/
0534
Logic High
Output
Current
I
OH
0.1
0.5
0.5
V
T
A
= 25°C
I
O
= 3.0 mA
I
O
= 2.4 mA
0.003
0.5
μA
T
A
= 25°C V
CC
= V
O
= 5.5V, I
F
= 0 mA
I
F
= 0 mA
T
A
= 25°C V
CC
= V
O
= 15V,
I
F
= 0 mA
6
1
50
Logic Low
Supply
Current
Logic High
Supply
Current
Input
Forward
Voltage
Input
Reverse
Breakdown
Voltage
Temperature
Coefficient
of Forward
Voltage
Input
Capacitance
I
CCL
100
400
μA
I
F
= 16 mA, V
O
= Open,
V
CC
= 15 V
I
F
= 0 mA, V
O
= Open,
V
CC
= 15 V
T
A
= 25°C
I
F
= 16 mA
3
1
I
CCH
0.05
4
μA
V
F
1.5
1.7
1.8
V
BV
R
5
V
I
R
=10 μA
1
ΔV
F
ΔT
A
-1.6
mV/
°C
I
F
= 16 mA
C
IN
60
pF
f = 1 MHz, V
F
= 0 V
1
*All typicals at T
A
= 25°C.
10