IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option 060)
Characteristic
HCPL-
2530/2531/4534
HCPL-
0530/0531/0534
I-IV
I-III
I-II
55/100/21
2
567
1050
V
peak
V
peak
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test
with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample Test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure.)
Case Temperature
Input Current**
Output Power**
Insulation Resistance at T
S
, V
IO
= 500 V
*
Symbol
Unit
I-IV
I-III
55/100/21
2
V
IORM
V
PR
630
1181
V
PR
V
IOTM
945
6000
840
4000
V
peak
V
peak
T
S
I
S,INPUT
P
S,OUTPUT
R
S
175
230
600
> 10
9
150
230
600
> 10
9
˚C
mA
mW
:
Refer to the optocoupler section of the Isolation and Control Components Designer's Catalog, under Product Safety Regulations section,
IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
Note:
Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.