 浏览型号HCPL-2611-000E的Datasheet PDF文件第5页浏览型号HCPL-2611-000E的Datasheet PDF文件第6页浏览型号HCPL-2611-000E的Datasheet PDF文件第7页浏览型号HCPL-2611-000E的Datasheet PDF文件第8页浏览型号HCPL-2611-000E的Datasheet PDF文件第10页浏览型号HCPL-2611-000E的Datasheet PDF文件第11页浏览型号HCPL-2611-000E的Datasheet PDF文件第12页浏览型号HCPL-2611-000E的Datasheet PDF文件第13页  
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-26xx; 46xx; 6N13x Option 060 Only)
Description
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 450 V
rms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and sample test, t
m
= 10 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 60 sec)
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Characteristic
I-IV
I-IV
40/85/21
2
630
1181
Unit
V
IORM
V
PR
V
peak
V
peak
V
PR
1008
V
peak
V
IOTM
T
S
6000
175
230
600
≥10
9
V
peak
°C
mA
mW
Ω
I
S,INPUT
P
S,OUTPUT
R
S
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCNW137/2601/2611 Only)
Description
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 600 V
rms
for rated mains voltage ≤ 1000 V
rms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and sample test, t
m
= 10 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 60 sec)
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Characteristic
I-IV
I-III
40/85/21
2
1414
2651
Unit
V
IORM
V
PR
V
peak
V
peak
V
PR
2262
V
peak
V
IOTM
T
S
8000
150
400
700
≥10
9
V
peak
°C
mA
mW
Ω
I
S,INPUT
P
S,OUTPUT
R
S
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
9