AC Electrical Specifications
Unless otherwise noted, all typicals and figures are at the nominal operating conditions of V
IN+
= 0, V
IN-
= 0 V, V
DD1
=
V
DD2
= 5 V and T
A
= 25°C; all Min./Max. specifications are within the Recommended Operating Conditions.
Parameter
V
OUT
Bandwidth
(-3 dB) sine wave.
V
OUT
Noise
V
IN
to V
OUT
Signal Delay
(50 – 10%)
V
IN
to V
OUT
Signal Delay
(50 – 50%)
V
IN
to V
OUT
Signal Delay
(50 – 90%)
V
OUT
Rise/ Fall Time
(10 – 90%)
Common Mode
Transient
Immunity
Power Supply
Rejection
Symbol
BW
N
OUT
t
PD10
Min.
50
Typ.
100
31.5
2.03
Max.
Unit
kHz
mVrms
Test Conditions
V
IN+
= 200 mV
pk-pk
V
IN+
= 0.0 V
V
IN+
= 0 mV to 150 mV
step.
Measured at output of
MC34081 on Figure 15.
Fig.
12,13
Note
13
14,15
3.3
µs
t
PD50
3.47
5.6
t
PD90
4.99
9.9
t
R/F
2.96
6.6
CMTI
10.0
15.0
kV/µs
V
CM
= 1 kV, T
A
= 25°C
16
14
PSR
170
mVrms
With recommended
application circuit.
15
Package Characteristics
Parameter
Input-Output
Momentary Withstand
Voltage
Resistance
(Input-Output)
Capacitance
(Input-Output)
Symbol
V
ISO
Min.
3750
Typ.
Max.
Unit
Vrms
Test Condition
RH < 50%,
t = 1 min.
T
A
= 25°C
V
I-O
= 500 V
DC
ƒ = 1 MHz
Fig.
Note
16,17
R
I-O
C
I-O
>10
9
1.2
Ω
pF
18
18