Table 1. Absolute Maximum Ratings
(1)
Parameter
RF Input Power
Supply Voltage
Reference Voltage
Case Operating Temperature
Storage Temperature
NOTE(S):
(1)
Symbol
Pin
Vcc
Vref
Tc
Tstg
Min
—
—
—
–30
–55
Nominal
3.0
3.4
3.0
25
—
Max
6.0
5.0
3.3
+110
+125
Unit
dBm
Volts
Volts
°C
°C
No damage assuming only one parameter is set at limit at a time with all other parameters set at or below nominal value.
Table 2. Recommended Operating Conditions
Parameter
Supply Voltage
Reference Voltage
Operating Frequency
Operating Temperature
Symbol
Vcc
Vref
Fo
To
Min
3.2
2.9
824.0
–30
Nominal
3.4
3.0
836.5
+25
Max
4.2
3.1
849.0
+85
Unit
Volts
Volts
MHz
°C