IN74HC4053A
ADDITIONAL APPLICATION CHARACTERISTICS (GND = 0.0 V)
VCC
VEE
V
Limit*
Symbol
BW
Parameter
Test Conditions
fin=1 MHz Sine Wave
Adjust fin Voltage to Obtain 0 dBm at VOS
Increase fin Frequence Until dB Meter
Reads -3 dB
V
Unit
25 °C
Maximum On-
Channel
Bandwidth or
Minimum
Frequency
Response
MHz
2.25
4.50
6.00
-2.25
-4.50
-6.00
120
120
120
RL =50 Ω, CL=10 pF
(Figure 5)
-
-
Off-Channel
Feedthrough
Isolation
fin= Sine Wave
Adjust fin Voltage to Obtain 0 dBm at VIS
fin = 10 kHz, RL =600 Ω, CL=50 pF
dB
2.25
4.50
6.00
-2.25
-4.50
-6.00
-50
-50
-50
(Figure 6)
2.25
4.50
6.00
-2.25
-4.50
-6.00
-40
-40
-40
fin = 1.0 MHz, RL =50 Ω, CL=10 pF
Feedthrough
Noise, Channel
Select Input to
Common O/I
(Figure 7)
mVpp
VIN≤ 1 MHz Square Wave (tr = tf = 6 ns)
Adjust RL at Setup so that IS= 0 A Enable
= GND
2.25
4.50
6.00
-2.25
-4.50
-6.00
25
105
135
RL =600 Ω, CL=50 pF
2.25
4.50
6.00
-2.25
-4.50
-6.00
35
145
190
RL =10 Ω, CL=10 pF
-
Crosstalk
fin= Sine Wave
dB
Between Any
Two Switches
(Figure 14)
Adjust fin Voltage to Obtain 0 dBm at VIS
fin = 10 kHz, RL =600 Ω, CL=50 pF
2.25
4.50
6.00
-2.25
-4.50
-6.00
-50
-50
-50
2.25
4.50
6.00
-2.25
-4.50
-6.00
-60
-60
-60
fin = 1 MHz, RL =50 Ω, CL=10 pF
THD
Total Harmonic
Distortion
(Figure 16)
%
fin= 1 kHz, RL =10 kΩ, CL=50 pF
THD = THDMeasured - THDSource
VIS =4.0 VPP sine wave
2.25
4.50
6.00
-2.25
-4.50
-6.00
0.10
0.08
0.05
VIS =8.0 VPP sine wave
VIS =11.0 VPP sine wave
* Limits not tested. Determined by design and verified by qualification.
Rev. 00