 浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第1页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第2页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第3页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第4页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第6页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第7页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第8页浏览型号LTC2934CTS8-2-TRMPBF的Datasheet PDF文件第9页  
LTC2934  
TYPICAL PERFORMANCE CHARACTERISTICS A = 25°C, unless otherwise noted1  
Supplꢃ Current vs Rꢄ  
Input Voltage  
Supplꢃ Current vs MR Input Voltage  
250  
200  
150  
100  
50  
5
4
3
2
1
0
V
CC  
= 3.6V  
V
CC  
= 3.6V  
0
1
1.5  
2
2.5  
3
4
0
0.5  
3.5  
1
1.5  
2
2.5  
3
4
0
0.5  
3.5  
RT INPUT VOLTAGE (V)  
MR INPUT VOLTAGE (V)  
2934 G07  
2934 G08  
PIN FUNCTIONS  
ADJ: Reset Threshold Adjustment Input. Tie to resistive  
divider between monitored voltage and GND to configure  
desired reset threshold. See the Applications Information  
PFO: Power-Fail Output. PFO pulls low when monitored  
voltage falls below the power-fail (PFI) threshold. PFO  
is released when the PFI voltage rises above the power-  
fail threshold by 2.5%. PFO is available with open-drain  
(LTC2934-1)oractivepull-up(LTC2934-2)outputs. Leave  
open if unused.  
section for details. Tie to V if unused.  
CC  
EꢂposedPadDFNOnlꢃx:ExposedPadmaybeleftoating  
or connected to device ground.  
RST: Reset Output. RST pulls low when monitored volt-  
age falls below the reset threshold. RST is released after  
monitored voltage exceeds the reset threshold plus 5%  
hysteresisandafterresettimerhasexpired.RSTisavailable  
withopen-drain(LTC2934-1)oractivepull-up(LTC2934-2)  
outputs. Leave open if unused.  
GND: Device Ground.  
MR: Manual Reset Input. Attach a push-button switch  
between this input and ground. A logic low on this input  
pulls RST low. When the MR input returns to logic high,  
RST returns high after the reset timer has expired. Tie to  
V
if unused.  
CC  
Rꢄ: Reset Timeout Selection Input. Tie to GND or V for  
CC  
PFI: Power-Fail Threshold Adjustment Input. Tie to  
resistive divider between monitored voltage and GND  
to configure desired power-fail threshold. See the  
Applications Information section for details. Tie to V or  
GND if unused.  
desired reset timeout. Tie low for 15ms delay or high for  
200ms delay.  
V : Power Supply Input. Bypass V with 0.1μF to  
CC  
CC  
CC  
GND.  
2934f  