欢迎访问ic37.com |
会员登录 免费注册
发布采购

R95-510A-130 参数 Datasheet PDF下载

R95-510A-130图片预览
型号: R95-510A-130
PDF下载: 下载PDF文件 查看货源
内容描述: 突发脉冲雷达液位变送器 [Pulse Burst Radar Level Transmitter]
分类和应用: 脉冲雷达
文件页数/大小: 48 页 / 1410 K
品牌: MAGNETROL [ MAGNETROL INTERNATIONAL, INC. ]
 浏览型号R95-510A-130的Datasheet PDF文件第2页浏览型号R95-510A-130的Datasheet PDF文件第3页浏览型号R95-510A-130的Datasheet PDF文件第4页浏览型号R95-510A-130的Datasheet PDF文件第5页浏览型号R95-510A-130的Datasheet PDF文件第7页浏览型号R95-510A-130的Datasheet PDF文件第8页浏览型号R95-510A-130的Datasheet PDF文件第9页浏览型号R95-510A-130的Datasheet PDF文件第10页  
Œ
1.2
QuickStart Mounting
NOTE: Confirm the configuration style and process connection (size
and type) of the PULSAR radar transmitter. Make sure it matches
the requirements of the installation before continuing with the
QuickStart installation.
Œ
Confirm the model and serial numbers on the nameplates
of PULSAR electronics and antenna are identical.


Œ
1.2.1 Antenna

Ž

Carefully place the antenna into the vessel. Mount in a
location equal to
1
2
the radius of tank top. Do not mount in
center of vessel nor closer than 18" (45 cm) of tank wall.
Ž
Secure the antenna to the vessel.

Leave the protective plastic cap in place until ready to
install the transmitter.
NOTE: Do not use sealing compound or TFE tape on antenna connec-
tion to transmitter. This connection is sealed by a Viton
®
O-ring.
1.2.2 Transmitter
1. Remove the protective plastic cap from the top of the
antenna and store for future use. Make sure the bottom of
the Universal connector (TFE)

and inside of the antenna
are clean and dry. Clean with isopropyl alcohol and cotton
swabs if necessary.
2. Place the transmitter on the antenna.
3. Ensure the housing/launcher set screw is loose and the
housing can be turned. Align the antenna index mark so it
is at an angle of 45° to a line from the radar unit to the
nearest tank wall. Do not optimize the Quality (signal
strength) at one level in the vessel.
4. Rotate the transmitter so that it is in the most convenient
position for wiring, configuring, and viewing.
5. While keeping the housing and launcher aligned, tighten
both the housing/launcher set screw and large Universal
connector Hex nut. Tighten the universal connector to
30 ft./lbs of force. A torque wrench is highly desirable.
DO NOT LEAVE HAND TIGHT.
• Do not place insulating material around any part of the
Radar transmitter including the antenna flange.
1.3
QuickStart Wiring
Index
Mark
1 dot: GP/IS
2 dots: XP
Set Screw
Universal
Connector
WARNING!
Explosion hazard. Do not remove covers unless power
has been switched off or the area is known to be non-
hazardous.
NOTE: Make sure the electrical wiring to the PULSAR radar transmitter
is complete and in compliance with all regulations and codes.
6
58-601 Pulsar
®
Radar Transmitter