DC/DC CONVERTER 1W,
Reinforced Insulation, Medical Safety
MAU400 SERIES
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
Single Output
DC / DC
Converter
-Vin
-Out
+Out
Copper Strip
Cout
Copper Strip
Resistive
Scope
Load
+Vin
Dual Output
DC / DC
Converter
-Vin
+Out
Com.
-Out
Copper Strip
Cout
Copper Strip
Cout
Copper Strip
Scope
Scope
Resistive
Load
Test Setup
Technical Notes
Maximum Capacitive Load
The MAU400 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 220µF maximum capacitive load for dual outputs and 680µF capacitive load for
single outputs. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0
Ω
at 100 KHz) capacitor of a 2.2µF for the 5V input devices, a 1.0µF for the 12V input devices.
+
DC Power
Source
-
+
Cin
-Vin
-Out
+Vin
DC / DC
Converter
+Out
Load
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.5µF capacitors at the output.
+
DC Power
Source
-
-Vin
+Vin
Single Output
DC / DC
Converter
-Out
+Out
+
DC Power
Source
-
+Vin
+Out
Dual Output
DC / DC Com.
Converter
Cout
Cout
Load
Load
Cout
Load
-Vin
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
Air Flow
50mm / 2in
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail:
sales@minmax.com.tw
Minmax Technology Co., Ltd.
2013/01/24 REV:10
Page 4 of 4