System Reset (with built-in watchdog timer) MM1096  
MITSUMI  
(Except where noted otherwise, MM1096A : VCC=3.6V, Ta=25°C, MM1096B : VCC=5.0V)  
(Except where noted otherwise, resistance unit is )  
Electrical Characteristics (DC)  
Item  
Symbol  
Measurement conditions  
Min. Typ. Max.  
Units  
3.6V  
2.8V  
5.0V  
4.0V  
MM1096A  
MM1096B  
8
VCC  
VCC  
VCC input  
pulse width  
TPI  
µs  
8
CK input pulse width  
CK input cycle  
TCKW  
TCK  
3
µs  
µs  
CK  
or  
20  
Watchdog timer  
TWD  
TWR  
TPR  
CT=0.02µF  
CT=0.02µF  
25  
1
50  
2
75  
3
ms  
ms  
ms  
monitoring time 1  
*
Reset time for  
watchdog timer 2  
*
Reset hold time for  
5
10  
15  
CT=0.02µF, VCC  
power supply rise  
3
*
--------------------------------------------------------------------------  
Output delay time from VCC  
4
TPD  
tR  
RESET pin, RL=10k, CL=20pF  
2
10  
4.0  
1.0  
µs  
µs  
µs  
*
--------------------------------------------------------------------------  
Output rise time 5  
RESET pin, RL=10k, CL=20pF  
--------------------------------------------------------------------------  
2.0  
0.2  
*
Output fall time 5  
tF  
RESET pin, RL=10k, CL=20pF  
*
Notes:  
1 Monitoring time is the time from the last pulse (negative edge) of the timer clear clock pulse until reset  
pulse output. In other words, reset output is output if a clock pulse is not input during this time.  
2 Reset time means reset pulse width. However, this does not apply to power ON reset.  
*
*
*
3 Reset hold time is the time from when VCC exceeds detection voltage (VSH) during power ON reset until  
-----------------------------------------------  
reset release (RESET output high).  
4 Output delay time is the time from when power supply voltage drops below detection voltage (VSL) until  
*
reset (-R----------E---------S----------E---------T-------- output low).  
5 Voltage range when measuring output rise and fall is 10~90%.  
6 Watchdog timer monitoring time (TWD), watchdog timer reset time (TWR) and reset hold time (TPR) during  
power supply rise can be changed by varying CT capacitance. The times are expressed by the following  
formulae.  
*
*
.
TPR (ms) = 500 CT (µF)  
.
.
TWD (ms) = 2500 CT (µF)  
.
.
TWR (ms) = 100 CT (µF)  
.
Example : When CT=0.02µF  
.
TPR = 10ms  
.
.
TWD = 50ms  
.
.
TWR = 2ms  
.