MC10129
ELECTRICAL CHARACTERISTICS
TEST VOLTAGE VALUES (Volts)
IBM INPUT LEVELS (6.)
HYSTERESIS MODE
@ Test Temperature
–30°C
V
V
V
′
V
′
V
′′
V
′′
V
′′′
V
′′′
V
V
(5.)
V
EE
IH
IL
IHA
ILA
IHA
ILA
IHA
ILA
CC
3.11
3.11
3.11
0.150
0.150
0.150
2.90
2.60
2.30
2.00
1.70
1.40
2.20
1.90
1.60
1.30
1.00
0.70
+5.0
+5.0
+5.0
–5.2
–5.2
–5.2
+25°C
1.700
0.70
+85°C
TEST VOLTAGE APPLIED TO PINS LISTED BELOW
Pin
Under
Test
Characteristic
Symbol
Gnd
V
V
V
′
V
′
V
′′
V
′′
V
′′′
V
′′′
(5.)
V
IH
IL
IHA
ILA
IHA
ILA
IHA
ILA
CC
EE
Negative Power Supply
Drain Current
I
8
8
9
9
8
5,8
1,5,16
1,16
E
Positive Power Supply
Drain Current
I
9
4,6,
7,13
9
9
5,8
5,8
1,16
1,16
CC
Input Current
I
4
6
4
6
7
9
9
9
9
9
9
9
8
8
8
8
8
8
8
1,16
1,16
1,16
1,16
1,16
1,16
1,16
inH
7
10
11
12
13
13
I
(1.)
4
6
4
6
9
9
9
9
8
8
8
8
1,16
1,16
1,16
1,16
CBO
7
7
13
13
I
10
11
12
9
9
9
8
8
8
1,16
1,16
1,16
inL
Output Voltage
Logic 1
V
2
3
2
3
4
6
4
6
9
9
9
9
5,8
5,8
8
1,16
1,16
1,5,16
1,5,16
OH
8
Output Voltage
Logic 0
V
2
3
2
3
4
6
4
6
9
9
9
9
5,8
5,8
8
1,16
1,16
1,5,16
1,5,16
OL
8
Threshold Voltage
Logic 1
V
2 (2.)
2
4
4
4
9
9
9
9
9
9
5,8
5,8
5,8
5,8
8
1,16
1,16
OHA
2
1,16
2
4
1,16
1,5,16
1,5,16
2 (3.)
2 (4.)
4
4
8
Threshold Voltage
Logic 0
V
2 (2.)
2
2 (2.)
2
2 (3.)
2 (4.)
4
4
4
9
9
9
9
9
9
5,8
5,8
5,8
5,8
8
1,16
1,16
OLA
1,16
4
1,16
1,5,16
1,5,16
4
4
8
Switching Times
Propagation Delay
+5.0V +2.40V
Figure
+7.0V
–3.2V
+2.0V
Data Input
Clock Input
Strobe Input
t
14
14
Figure 3
Figure 3
9
9
5,8
5,8
1,16
1,16
7+14+
t
7–14–
t
t
14
14
Figure 6
Figure 6
9
9
5,8
5,8
1,16
1,16
11–14+
11–14–
t
14
14
7
7
Figure 4
Figure 4
9
9
5,8
5,8
1,16
1,16
12+14+
t
t
12–14–
Reset Input
14
7
Figure 5
9
5,8
1,16
10+14–
Hysteresis Mode
t
t
14
14
Figure 3
Figure 3
9
9
8
8
1,5,16
1,5,16
7+14+
7–14–
Setup Time
Hold Time
Rise Time
t
14
14
14
Figure 7
Figure 7
Figure 3
9
9
9
5,8
5,8
5,8
1,16
1,16
1,16
setup
t
hold
t+
Fall Time
t–
14
Figure 3
9
5,8
1,16
1. Pin 5 to V , V to Data input one at a time.
EE IL
2. Outputlatchedtologichighstatepriortotest. V
′, V ′ arestandardlogic1andlogic0MTTLthresholdvoltages. V
IHA ILA
′′, V ′′, V
ILA
′′′ andV ′′′ arelogic1and
IHA ILA
IHA
logic 0 threshold voltages in the hysteresis mode as shown in Figure 1 on page 3–2.
3. Input level on data input taken from +0.4V up to voltage level given.
4. Input level on data input taken from +4.0V down to voltage level given.
5. Operation and limits shown also apply for V
= +6.0V.
6. When testing, choose either TTL or IBM input levels.
CC
MOTOROLA
3–4
MECL Data
DL122 — Rev 6