CF5036 series
Switching Characteristics
3.3V operation
V
CC
= 3.0 to 3.6V, GND = 0V, Ta =
−40
to +85°C unless otherwise noted.
Rating
Parameter
Symbol
Conditions
Min
Output duty cycle 1
Duty1
Measurement cct. 4, measured
at output crossing point,
Ta = 25°C, V
CC
= 3.3V
Measurement cct. 4,
measured at 50% output swing,
Ta = 25°C, V
CC
= 3.3V
f
<
350MHz
f
≥
350MHz
f
<
350MHz
f
≥
350MHz
5036G×: f = 80MHz
5036A×: f = 120MHz
Measurement cct. 4,
Ta = T
OPR
,
Peak to peak of single output
waveform
5036B×: f = 180MHz
5036C×: f = 250MHz
5036D×: f = 400MHz
5036E×: f = 600MHz
5036F×: f = 700MHz
Output rise time
Output fall time
Output enable time
*2
Output disable time
t
r
t
f
t
OE
t
OD
Measurement cct. 4, 20 to 80% output swing
Measurement cct. 4, 80 to 20% output swing
Measurement cct. 1, Ta = 25°C
Measurement cct. 1, Ta = 25°C
45
40
45
40
0.4
0.4
0.4
0.4
0.4
0.4
0.4
–
–
–
–
Typ
–
–
–
–
–
–
–
–
–
–
–
0.3
0.3
–
–
Max
55
60
55
60
–
–
–
–
–
–
–
0.7
0.7
2
200
%
%
%
%
V
V
V
V
V
V
V
ns
ns
ms
ns
Unit
Output duty cycle 2
Duty2
Output swing
*1
V
Opp
*1. The said values are measured by using the NPC standard jig.
*2. The built-in oscillator stop function does not operate with normal output immediately when OE goes HIGH. Instead, normal output occurs after the
oscillator startup time has elapsed.
SEIKO NPC CORPORATION —6