Output Circuit Diagram
Long-distance type
Model
Ope-
rating
status
Timing chart
Output circuit
4
Brown
Load
+V
Setting point
Non-sensing zone
Unstable
sensing zone Stable sensing zone
Main
circuit
3
E2EQ-X4X1
E2EQ-X8X1
E2EQ-X15X1
E2EQ-X4X1-M1J
E2EQ-X8X1-M1J
E2EQ-X15X1-M1J
Blue
0V
Sensing
object
NO
(%)
100
Rated
sensing
distance
80(TYP)
0
Lit
Not lit
Lit
Not lit
ON
OFF
Green
indicator
Red
indicator
Control
output
Note:
1. The load can be connected to either the +V or the 0-V line.
2. Since there is no polarity, there is no need to pay attention
to the brown or blue polarity.
Wiring
1
2
3
4
Note:
Terminals
B
and
C
are not used.
Standard
Model
Ope-
rating
status
Timing chart
Output circuit
Brown
Setting point
Non-sensing zone
Unstable
sensing zone Stable sensing zone
Main circuit
1
Main
circuit
Load
+V
E2EQ-X3D1
E2EQ-X7D1
E2EQ-X10D1
E2EQ-X3D1-M1GJ
E2EQ-X7D1-M1GJ
E2EQ-X10D1-M1GJ
Sensing
object
(%)
100
80(TYP)
0
4
Blue
0V
NO
Rated
sensing
distance
Lit
Green indicator
Not lit
Lit
Red indicator
Not lit
ON
Control output
OFF
Note:
The Load can be connected to either the
+V or the 0-V line.
Wiring
A
B
C
Note:
Terminals
B
and
C
are not used.
D
Connecting Plug-in models
Model
E2EQ-X#X1-M1J
E2EQ-X#D1-M1GJ
Connector relay type
E2EQ-X#X1-M1J
Connection
Main circuit
1
2
3
4
Sensor I/O Connectors
XS2F-D42#-#C0-A
1
2
3
4
Connector relay type
E2EQ-X#D1-M1GJ
Brown
not connected
Blue (+)
Black (-)
Main circuit
1
2
3
4
Sensor I/O Connectors
XS2F-D42#-#A0-A
1
2
3
4
Brown (+)
Blue (-)
E-36
Proximity Sensors