VIPER27  
Operation descriptions  
When the feedback pin voltage reaches the threshold VFBlin an internal current generator  
starts to charge the feedback capacitor (CFB) and when the feedback voltage reaches the  
VFBolp threshold, the converter is turned off and the start up phase is activated with reduced  
value of IDDch to 0.6 mA, see Table 7 on page 6.  
During the first start up phase of the converter, after the soft-start up time, tSS, the output  
voltage could force the feedback pin voltage to rise up to the VFBolp threshold that switches  
off the converter itself.  
To avoid this event, the appropriate feedback network has to be selected according to the  
output load. More the network feedback fixes the compensation loop stability. The Figure 28  
on page 22 and Figure 29 show the two different feedback networks.  
The time from the over load detection (VFB = VFBlin) to the device shutdown  
(VFB = VFBolp) can be set by CFB value (see Figure 28 on page 22 and Figure 29), using the  
formula:  
Equation 5  
V
FBolp VFBlin  
---------------------------------------  
×
TOLP delay = CFB  
3μA  
In the Figure 28, the capacitor connected to FB pin (CFB) is part of the compensation circuit  
as well as it needs to activate the over load protection (see equation 5).  
After the start up time, tSS, during which the feedback voltage is fixed at VFBlin, the output  
capacitor could not be at its nominal value and the controller interprets this situation as an  
over load condition. In this case, the OLP delay helps to avoid an incorrect device shut down  
during the start up phase.  
Owing to the above considerations, the OLP delay time must be long enough to by-pass the  
initial output voltage transient and check the over load condition only when the output  
voltage is in steady state. The output transient time depends from the value of the output  
capacitor and from the load.  
When the value of the CFB capacitor calculated for the loop stability is too low and cannot  
ensure enough OLP delay, an alternative compensation network can be used and it is  
showed in Figure 29 on page 22.  
Using this alternative compensation network, two poles (fPFB, fPFB1) and one zero (fZFB) are  
introduced by the capacitors CFB and CFB1 and the resistor RFB1  
.
The capacitor CFB introduces a pole (fPFB) at higher frequency than fZB and fPFB1. This pole  
is usually used to compensate the high frequency zero due to the ESR (equivalent series  
resistor) of the output capacitance of the fly-back converter.  
The mathematical expressions of these poles and zero frequency, considering the scheme  
in Figure 29 are reported by the equations below:  
Equation 6  
1
fZFB  
=
2πCFB1 RFB1  