SLLS755H – JULY 2006 – REVISED MAY 2008
................................................................................................................................................................
www.ti.com
ELECTRICAL CHARACTERISTICS: V
CC1
and V
CC2
at 5-V
(1)
OPERATION
over recommended operating conditions (unless otherwise noted)
PARAMETER
SUPPLY CURRENT
ISO7220x
ISO7221
I
CC1
ISO7220A, ISO7220B
ISO7221A, ISO7221B
ISO7220C, ISO7220M
ISO7221C, ISO7221M
ISO7220x
ISO7221x
I
CC2
ISO7220A, ISO7220B
ISO7221A, ISO7221B
ISO7220C, ISO7220M
ISO7221C, ISO7221M
V
OH
V
OL
High-level output voltage
Low-level output voltage
Quiescent
1 Mbps
25 Mbps
Quiescent
1 Mbps
25 Mbps
V
I
= V
CC
or 0 V, no load
V
I
= V
CC
or 0 V, no load
V
I
= V
CC
or 0 V, no load
V
I
= V
CC
or 0 V, no load
V
I
= V
CC
or 0 V, no load
V
I
= V
CC
or 0 V, no load
I
OH
= –4 mA, See
I
OH
= –20
µA,
See
I
OL
= 4 mA, See
I
OL
= 20
µA,
See
V
CC
– 0.8
V
CC
– 0.1
1
8.5
2
10
4
12
16
8.5
17
10
20
12
4.6
5
0.2
0
150
IN from 0 V to V
CC
IN at V
CC
, V
I
= 0.4 sin (4E6πt)
V
I
= V
CC
or 0 V, See
25
10
–10
1
50
0.4
0.1
2
17
3
18
9
22
31
17
32
18
34
22
V
V
mV
µA
pF
kV/µs
mA
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
I(HYS)
Input voltage hysteresis
I
IH
I
IL
C
I
CMTI
(1)
High-level input current
Low-level input current
Input capacitance to ground
Common-mode transient immunity
For the 5-V operation, V
CC1
or V
CC2
is specified from 4.5 V to 5.5 V.
For the 3-V operation, V
CC1
or V
CC2
is specified from 3 V to 3.6 V.
SWITCHING CHARACTERISTICS: V
CC1
and V
CC2
at 5-V OPERATION
over recommended operating conditions (unless otherwise noted)
PARAMETER
t
pLH
,
t
pHL
PWD
t
pLH
,
t
pHL
PWD
t
pLH
,
t
pHL
PWD
t
pLH
,
t
pHL
PWD
Propagation delay
Pulse-width distortion |t
pHL
– t
pLH
|
(1)
Propagation delay
Pulse-width distortion |t
pHL
– t
pLH
|
(1)
Propagation delay
Pulse-width distortion |t
pHL
– t
pLH
|
Propagation delay
Pulse-width distortion |t
pHL
– t
pLH
|
(1)
ISO722xA
t
sk(pp)
Part-to-part skew
(2)
(1)
TEST CONDITIONS
ISO722xA
MIN
280
TYP
405
1
MAX
475
14
70
3
42
2
16
1
180
17
10
3
UNIT
ISO722xB
See
ISO722xC
42
55
1
ns
22
32
1
ISO722xM
6
10
0.5
ISO722xB
ISO722xC
ISO722xM
ns
(1)
(2)
4
Also referred to as pulse skew.
t
sk(pp)
is the magnitude of the difference in propagation delay times between any specified terminals of two devices when both devices
operate with the same supply voltages, at the same temperature, and have identical packages and test circuits.
Copyright © 2006–2008, Texas Instruments Incorporated
Product Folder Link(s):