SCES587A − AUGUST 2004 − REVISED OCTOBER 2004
SN74AVCH16T245
16 BIT DUAL SUPPLY BUS TRANSCEIVER
WITH CONFIGURABLE VOLTAGE TRANSLATION AND 3 STATE OUTPUTS
recommended operating conditions (see Notes 4 through 8)
VCCI
VCCA
VCCB
VIH
Supply voltage
Supply voltage
1.2 V to 1.95 V
High-level input
voltage
Data inputs
(see Note 7)
1.95 V to 2.7 V
2.7 V to 3.6 V
1.2 V to 1.95 V
VIL
Low-level input
voltage
Data inputs
(see Note 7)
DIR
(referenced to VCCA)
(see Note 8)
DIR
(referenced to VCCA)
(see Note 8)
1.95 V to 2.7 V
2.7 V to 3.6 V
1.2 V to 1.95 V
1.95 V to 2.7 V
2.7 V to 3.6 V
1.2 V to 1.95 V
1.95 V to 2.7 V
2.7 V to 3.6 V
0
Active state
VO
Output voltage
3-state
1.2 V
1.4 V to 1.6 V
IOH
High-level output current
1.65 V to 1.95 V
2.3 V to 2.7 V
3 V to 3.6 V
1.2 V
1.4 V to 1.6 V
IOL
Low-level output current
1.65 V to 1.95 V
2.3 V to 2.7 V
3 V to 3.6 V
∆t/∆v
Input transition rise or fall rate
0
0
High-level input
voltage
VCCA
×
0.65
1.6
2
VCCA
×
0.35
0.7
0.8
3.6
VCCO
3.6
−3
−6
−8
−9
−12
3
6
8
9
12
5
ns/V
mA
mA
V
V
VCCO
MIN
1.2
1.2
VCCI
×
0.65
1.6
2
VCCI
×
0.35
0.7
0.8
MAX
3.6
3.6
UNIT
V
V
V
V
VIH
V
VIL
VI
Low-level input
voltage
Input voltage
V
TA
Operating free-air temperature
−40
85
°C
NOTES: 4. VCCI is the VCC associated with the data input port.
5. VCCO is the VCC associated with the output port.
6. All unused data inputs of the device must be held at VCCI or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs,
literature number SCBA004.
7. For VCCI values not specified in the data sheet, VIH min = VCCI
×
0.7 V, VIL max = VCCI
×
0.3 V.
8. For VCCI values not specified in the data sheet, VIH min = VCCA
×
0.7 V, VIL max = VCCA
×
0.3 V.
4
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265