www.ti.com
SN54LVC374A, SN74LVC374A
OCTAL EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SCAS296N – JANUARY 1993 – REVISED MAY 2005
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN
V
CC
V
I
V
O
V
O
I
IK
I
OK
I
O
Supply voltage range
Input voltage range
(2)
Voltage range applied to any output in the high-impedance or power-off state
(2) (3)
Voltage range applied to any output in the high or low state
Input clamp current
Output clamp current
Continuous output current
Continuous current through V
CC
or GND
DB package
(4)
DGV package
(4)
DW
θ
JA
Package thermal impedance
package
(4)
N package
(4)
NS package
(4)
PW package
(4)
RGY package
(5)
T
stg
(1)
(2)
(3)
(4)
(5)
Storage temperature range
–65
V
I
< 0
V
O
< 0
–0.5
–0.5
–0.5
–0.5
MAX
6.5
6.5
6.5
V
CC
+ 0.5
–50
–50
±50
±100
70
92
58
69
60
83
37
150
°C
°C/W
UNIT
V
V
V
V
mA
mA
mA
mA
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
The value of V
CC
is provided in the recommended operating conditions table.
The package thermal impedance is calculated in accordance with JESD 51-7.
The package thermal impedance is calculated in accordance with JESD 51-5.
3