TC74HC132AP/AF/AFN
Operating Ranges (Note)
Characteristics
Supply voltage
Input voltage
Output voltage
Operating temperature
Symbol
V
CC
V
IN
V
OUT
T
opr
Rating
2 to 6
0 to V
CC
0 to V
CC
−40
to 85
Unit
V
V
V
°C
Note:
The operating ranges must be maintained to ensure the normal operation of the device.
Unused inputs must be tied to either VCC or GND.
Electrical Characteristics
DC Characteristics
Characteristics
Symbol
Test Condition
V
CC
(V)
2.0
Positive threshold
voltage
V
P
⎯
4.5
6.0
2.0
Negative threshold
voltage
V
N
⎯
4.5
6.0
2.0
Hysteresis output
voltage
V
H
⎯
4.5
6.0
2.0
I
OH
= −20 μA
High-level output
voltage
V
OH
V
IN
=
V
IH
or V
IL
I
OH
= −4
mA
I
OH
= −5.2
mA
I
OL
=
20
μA
Low-level output
voltage
V
OL
V
IN
=
V
IH
or V
IL
I
OL
=
4 mA
I
OL
=
5.2 mA
Input leakage
current
Quiescent supply
current
I
IN
I
CC
V
IN
=
V
CC
or GND
V
IN
=
V
CC
or GND
4.5
6.0
4.5
6.0
2.0
4.5
6.0
4.5
6.0
6.0
6.0
Min
1.0
2.3
3.0
0.30
1.13
1.50
0.3
0.6
0.8
1.9
4.4
5.9
4.18
5.68
⎯
⎯
⎯
⎯
⎯
⎯
⎯
Ta
=
25°C
Typ.
1.25
2.70
3.50
0.65
1.60
2.30
0.6
1.1
1.2
2.0
4.5
6.0
4.31
5.80
0.0
0.0
0.0
0.17
0.18
⎯
⎯
Max
1.50
3.15
4.20
0.9
2.0
2.6
1.0
1.4
1.7
⎯
⎯
⎯
⎯
⎯
0.1
0.1
0.1
0.26
0.26
±0.1
1.0
Ta
=
−40
to 85°C
Min
1.0
2.3
3.0
0.30
1.13
1.50
0.3
0.6
0.8
1.9
4.4
5.9
4.13
5.63
⎯
⎯
⎯
⎯
⎯
⎯
⎯
Max
1.50
3.15
4.20
0.9
2.0
2.6
1.0
1.4
1.7
⎯
⎯
⎯
⎯
⎯
0.1
0.1
0.1
0.33
0.33
±1.0
10.0
μA
μA
V
V
V
V
V
Unit
AC Characteristics
(C
L
=
15 pF, V
CC
=
5 V, Ta
=
25°C, input: t
r
=
t
f
=
6 ns)
Characteristics
Output transition time
Symbol
t
TLH
t
THL
t
pLH
t
pHL
Test Condition
⎯
Min
⎯
Typ.
4
Max
8
Unit
ns
Propagation delay time
⎯
⎯
11
18
ns
3
2007-10-01