ABSOLUTE MAXIMUM RATINGS
Supply voltage, V
+ referenced to V-
Supply voltage, V
S referenced to V-
Differential input voltage range
Power dissipation
Operating temperature range SAL, PAL, SCL, PCL packages
DA, DC packages
Storage temperature range
Lead temperature, 10 seconds
CAUTION: ESD Sensitive Device. Use static control procedures in ESD controlled environment.
-0.3V to +10.6V
±5.3V
-0.3V to +0.3V
600mW
0°C to +70°C
-55°C to +125°C
-65°C to +150°C
+260°C
OPERATING ELECTRICAL CHARACTERISTICS
T
A
= 25
°
C V+ = +5.0V unless otherwise specified
Parameter
Drain to Source Voltage
1
Initial Threshold Voltage
2
E-trim V
t
Range
Drain - Gate Connected
Voltage Tempco
Symbol
V+
V
t i
V
t
TCV
DS
0.990
1.000
-1.6
-0.3
0.0
+2.7
Initial Offset Voltage
3
V
OS i
1
5
1.000
ALD1121E
Min
Typ
Max
10.0
1.010
3.000
0.990
1.000
-1.6
-0.3
0.0
+2.7
1
5
1.000
Min
ALD1123E
Typ
Max
10.0
1.010
3.000
Unit
V
V
V
mV/°C
mV/°C
mV/°C
mV/°C
mV
I
D
= 5µA
I
D
= 50µA
I
D
= 68µA
I
D
= 500µA
I
DS
= 1µA T
A
= 21°C
Test
Conditions
Tempco of V
OS
Differential Threshold Voltage
4
Tempco of Differential
Threshold Voltage
4
Long Term Drift
Long Term Drift Match
Drain Source On Current
TCV
OS
DV
t
5
2.000
5
2.000
µV/°C
V
V
DS1
= V
DS2
TCDV
t
∆V
t
/∆t
∆V
t
/∆t
I
DS(ON)
0.033
-0.02
-5
3.0
-0.05
0.033
-0.02
-5
3.0
-0.05
mV/°C
mV
µV
mA
1000 Hours
1000 Hours
V
G
=V
D
= 5V V
S
= 0V
V
t
= 1.0
V
G
=V
D =
5V V
S =
0V
V
t
= 3.0
V
t
= 1.000V
Drain Source On Current
4
I
DS(ON)
0.8
0.8
mA
Initial Zero Tempco Voltage
3
Zero Tempco Current
Initial On-Resistance
3
On-Resistance Match
V
ZTC i
I
ZTC
R
ON i
∆R
ON
1.52
68
500
0.5
1.52
68
500
0.5
V
µA
Ω
%
V
GS
¡= 5V V
DS
= 0.1V
NOTES:
1. V+ must be the most positive supply rail and V- must be at the most negative supply rail. Source terminals other than those labeled as V- can be at
any voltage between V- and V+.
2. Initial Threshold Voltage is set at the factory. If no EPAD Vt trimming is intended by user, then this is also the final or permanent threshold voltage
value.
3. Initial and Final values are the same unless deliberately changed by user.
4. These parameters apply only when V
t
of one or more of the devices are to be changed by user.
ALD1121E/ALD1123E
Advanced Linear Devices
3 of 14