 浏览型号EP1S30F1508I6ES的Datasheet PDF文件第108页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第109页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第110页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第111页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第113页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第114页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第115页浏览型号EP1S30F1508I6ES的Datasheet PDF文件第116页  
PLLs & Clock Networks  
Clock Multiplication & Division  
Each Stratix device enhanced PLL provides clock synthesis for PLL  
output ports using m/(n × post-scale counter) scaling factors. The input  
clock is divided by a pre-scale divider, n, and is then multiplied by the m  
feedback factor. The control loop drives the VCO to match fIN × (m/n).  
Each output port has a unique post-scale counter that divides down the  
high-frequency VCO. For multiple PLL outputs with different  
frequencies, the VCO is set to the least common multiple of the output  
frequencies that meets its frequency specifications. Then, the post-scale  
dividers scale down the output frequency for each output port. For  
example, if output frequencies required from one PLL are 33 and 66 MHz,  
set the VCO to 330 MHz (the least common multiple in the VCO’s range).  
There is one pre-scale counter, n, and one multiply counter, m, per PLL,  
with a range of 1 to 512 on each. There are two post-scale counters (l) for  
regional clock output ports, four counters (g) for global clock output  
ports, and up to four counters (e) for external clock outputs, all ranging  
from 1 to 1024 with a 50% duty cycle setting. The post-scale counters  
range from 1 to 512 with any non-50% duty cycle setting. The Quartus II  
software automatically chooses the appropriate scaling factors according  
to the input frequency, multiplication, and division values entered.  
Clock Switchover  
To effectively develop high-reliability network systems, clocking schemes  
must support multiple clocks to provide redundancy. For this reason,  
Stratix device enhanced PLLs support a flexible clock switchover  
capability. Figure 2–53 shows a block diagram of the switchover  
circuit.The switchover circuit is configurable, so you can define how to  
implement it. Clock-sense circuitry automatically switches from the  
primary to secondary clock for PLL reference when the primary clock  
signal is not present.  