欢迎访问ic37.com |
会员登录 免费注册
发布采购

AS1911S-T 参数 Datasheet PDF下载

AS1911S-T图片预览
型号: AS1911S-T
PDF下载: 下载PDF文件 查看货源
内容描述: 双电压微处理器监控电路,带有手动复位和看门狗 [Dual-Voltage Microprocessor Supervisory Circuits with Manual Reset and Watchdog]
分类和应用: 微处理器监控
文件页数/大小: 15 页 / 384 K
品牌: AMSCO [ AUSTRIAMICROSYSTEMS AG ]
 浏览型号AS1911S-T的Datasheet PDF文件第1页浏览型号AS1911S-T的Datasheet PDF文件第2页浏览型号AS1911S-T的Datasheet PDF文件第3页浏览型号AS1911S-T的Datasheet PDF文件第5页浏览型号AS1911S-T的Datasheet PDF文件第6页浏览型号AS1911S-T的Datasheet PDF文件第7页浏览型号AS1911S-T的Datasheet PDF文件第8页浏览型号AS1911S-T的Datasheet PDF文件第9页  
AS1910 - AS1915
Data Sheet - E l e c t r i c a l C h a r a c t e r i s t i c s
6 Electrical Characteristics
V
CC
= +2.7 to +3.6V for AS19xx-T/S/R, V
CC
= +2.1 to +2.75V for AS19xx- Z/Y, V
CC
= +1.53 to +2.0V for AS19xx-W/V;
T
AMB
= -40 to +125ºC (unless otherwise specified). Typ values @ T
AMB
= +25°C.
Table 4. Electrical Characteristics
Symbol
V
CC
Parameter
1
Conditions
T
AMB
= 0 to +85ºC
T
AMB
= -40 to +125ºC
V
CC
= +3.6V, No Load,
T
AMB
= -40ºC to +85ºC
V
CC
= +3.6V, No Load,
T
AMB
= -40 to +125ºC
V
CC2
= +2.5V
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
AS19xx-T
AS19xx-S
AS19xx-R
AS19xx-Z
AS19xx-Y
AS19xx-W
AS19xx-V
AS19xx-Z
AS19xx-Y
AS19xx-W
AS19xx-V
AS19xx-I
AS19xx-H
AS19xx-G
AS19xx-F
AS19xx-E
AS19xx-D
Min
1.0
1.2
Typ
Max
3.6
3.6
Units
V
Operating Voltage Range
I
CC
I
CC2
V
CC
Supply Current
(MRN and WDI Not Connected)
V
CC2
Supply Current
5.8
13
µA
21
2
µA
2.994
2.972
2.848
2.827
2.556
2.538
2.255
2.239
2.129
2.113
1.623
1.612
1.536
1.525
2.232
2.111
1.607
1.520
1.339
1.267
1.073
1.071
1.015
1.013
0.804
0.760
3.08
2.93
2.63
2.32
2.19
1.67
1.58
3.154
3.179
3.000
3.024
2.693
2.714
2.376
2.394
2.243
2.260
1.710
1.723
1.618
1.631
2.394
2.265
1.723
1.630
1.437
1.359
V
V
TH
V
CC
Reset Threshold
(V
CC
Falling)
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
T
AMB
= -40 to +85ºC
T
AMB
= -40 to +125ºC
2.237 2.313 2.387
2.116 2.188 2.258
1.610 1.665 1.718
1.523 1.575 1.625
1.342 1.388 1.432
1.270 1.313 1.355
1.11
1.05
1.146
1.149
1.084
1.087
0.862
0.816
V
V
TH2
V
CC2
Reset Threshold
0.806 0.833 0.860
0.762 0.788 0.813
www.austriamicrosystems.com
Revision 1.00
4 - 15