AWT6167R
Table 6: Operating Ranges
PARAMETER
Case Temperature (T
C
)
Supply Voltage (V
BATT
)
MIN
-20
3.0
TYP
-
3.5
MAX
85
4.8
UNIT
°C
V
V
BATT
= 4.8 V,
V
RAMP
= 0 V,
TX_EN = LOW,
No RF applied
COMMENTS
Power Supply Leakage Current
-
1
10
µA
Control Voltage Range
0.2
-
1.6
V
µs
V
RAMP
= 0.2 V, TX_EN =
LOW
→
High
P
IN
= 5 dBm
V
RAMP
= 0.2 V, TX_EN =
HIGH
→
LOW
P
IN
= 5 dBm
P
OUT
= -10 dBm
→P
MAX
(within 0.2 dB)
P
OUT
= P
MAX
→
-10 dBm
(within 0.2 dB)
Turn on time (T
ON
)
-
-
1
Turn off time (T
OFF
)
-
-
1
µs
Rise Time (T
RISE
)
Fall Time (T
FALL
)
V
RAMP
Input Capacitance
V
RAMP
Input Current
Duty Cycle
-
-
-
-
-
-
-
3
-
-
1
1
-
10
50
µs
µs
pF
µA
%
The device may be operated safely over these conditions; however, parametric performance is
guaranteed only over the conditions defined in the electrical specifications.
4
PRELIMINARY DATA SHEET - Rev 1.0
06/2005