EDS1232AATA
Electrical Specifications
•
All voltages are referenced to VSS (GND).
•
After power up, execute power up sequence and initialization sequence before proper device operation is achieved
(refer to the Power up sequence).
Absolute Maximum Ratings
Parameter
Voltage on any pin relative to VSS
Supply voltage relative to VSS
Short circuit output current
Power dissipation
Operating ambient temperature
Storage temperature
Symbol
VT
VDD, VDDQ
IOS
PD
TA
Tstg
Rating
–0.5 to +4.6
–0.5 to +4.6
50
1.0
0 to +70
–55 to +125
Unit
V
V
mA
W
°C
°C
Note
EO
Caution
Parameter
Supply voltage
Input high voltage
Input low voltage
Data Sheet E0386E60 (Ver. 6.0)
Exposing the device to stress above those listed in Absolute Maximum Ratings could cause
permanent damage. The device is not meant to be operated under conditions outside the limits
described in the operational section of this specification. Exposure to Absolute Maximum Rating
conditions for extended periods may affect device reliability.
Recommended DC Operating Conditions (TA = 0 to +70°C)
Symbol
min.
3.0
0
2.0
–0.3*
2
typ.
3.3
0
⎯
⎯
max.
3.6
0
VDD + 0.3*
0.8
1
Unit
V
V
V
V
Notes
Notes: 1. VIH (max.) = VDDQ + 1.5V (pulse width
≤
5ns).
2. VIL (min.) = –1.5V (pulse width
≤
5ns).
L
VSS
VIH
VIL
VDD, VDDQ
od
Pr
t
uc
4