GS4901B/GS4900B Preliminary Data Sheet
3.8 Video Timing Generator
The internal PCLK signal generated by the clock synthesis circuit is used to
produce horizontal, vertical, and frame based timing output signals.
The signals generated and available to the application layer via the TIMING_OUT
pins are: H Sync, H Blanking, V Sync, V Blanking, F Sync, F Digital, DE, 10FID,
AFS (GS4901B only), and USER_1~4. These signals are defined in
Additional information pertaining to the 10FID, AFS, and USER_1~4
signals can be found in the sub-sections below.
When the GS4901B/GS4900B is operating in Genlock mode, the H, V, and F
based output timing signals are synchronized to the H, V, and F reference signals
applied to the inputs by the application layer. The video timing outputs may be
offset from the input reference by programming the Genlock Offset registers
beginning at address 1Bh of the host interface (see
All TIMING_OUT signals have selectable polarity. The default polarities for each
signal are given in the descriptions in
3.8.1 10 Field ID Pulse
As described in
the 10 field ID (10FID) output signal is used in the
identification of film to video cadence. It is only generated for 29.97, 30, 59.94, and
60fps formats.
The 10FID pulse is generated on every 5
th
frame for 29.97 and 30fps formats, and
every 10
th
frame on 59.94 and 60fps formats.
By default, the 10FID signal is set HIGH on the leading edge of the H Sync output
for the duration of line 1 of field 1 at the start of the 10 field sequence. This is shown
in
Alternatively, by setting bit 4 of the Video_Control register at address 4Ch of the
host interface, the 10FID output signal may be configured to go HIGH (default
polarity) on the leading edge of the H Sync pulse of line 1 of the first field in the 10
field sequence, and be reset LOW on the leading edge of the H Sync pulse of line
1 of the second field in the 10 field sequence. This is shown in
Total Line
10FID Output
Line 1, Frame 1 every 'n' frames
Horizontal Sync Output
Line 1 every n frames where:
n = 5 @ 29.97 fps, 30 fps
n = 10 @ 59.94 fps, 60 fps
Figure 3-6: Default 10FID Output Timing
37703 - 0
April 2006
57 of 95