欢迎访问ic37.com |
会员登录 免费注册
发布采购

GSC24BC16 参数 Datasheet PDF下载

GSC24BC16图片预览
型号: GSC24BC16
PDF下载: 下载PDF文件 查看货源
内容描述: 2线串行EEPROM [2-WIRE SERIAL EEPROMS]
分类和应用: 可编程只读存储器电动程控只读存储器电可擦编程只读存储器
文件页数/大小: 9 页 / 284 K
品牌: GTM [ GTM CORPORATION ]
 浏览型号GSC24BC16的Datasheet PDF文件第1页浏览型号GSC24BC16的Datasheet PDF文件第2页浏览型号GSC24BC16的Datasheet PDF文件第3页浏览型号GSC24BC16的Datasheet PDF文件第4页浏览型号GSC24BC16的Datasheet PDF文件第5页浏览型号GSC24BC16的Datasheet PDF文件第6页浏览型号GSC24BC16的Datasheet PDF文件第7页浏览型号GSC24BC16的Datasheet PDF文件第9页  
ISSUED DATE :2006/06/14
REVISED DATE :
Current Address Read:
A current address read operation is initiated by issuing R/W=1 in the device address
word (refer to Figure 11). Since the internal address counter maintains the last address incremented by one
accessed during the last read or write operation, the internal address counter will always retain the last
address incremented by one.
Random Read:
To access a different address location that the one currently stored in the internal counter, a
random read operation is provided. The random read is actually a combination of a “dummy” byte write
sequence with a current address read command (refer to Figure 12). The “dummy” byte write loads a different
address into the internal counter, and the data can then be accessed using the current address read.
Sequential Read:
In order to access subsequent data word after a current address read or random read has
been initiated, the user should send an acknowledgment to the EEPROM chip after each data byte received. If
an acknowledgment is not received, then the chip will not send any more data and expect a STOP condition on
the next cycle to reset back to standby more (refer to Figure 13).
Sequential reads can be used to perform an entire chip read. Unlike the page write operation, the internal
counter will increment to the next row after the last byte of the page has been reached. When the address
reaches the last byte of the last memory page, the next address will increment to the 1
st
byte of the 1
st
memory
page.
Once the memory address limit is reached, the data word address will “roll over” and the sequential read will
continue. When the microcontroller does not respond with a zero but does generate a following stop condition,
the sequential read operations is terminated.
Figure 11. Current Address Read
Figure 12. Random Read
*
(
*
= DON’T CARE bit for 1K)
Figure 13. Sequential Read
GSC24BC01/02/02/04/08/16
Page: 8/9