欢迎访问ic37.com |
会员登录 免费注册
发布采购

IC41LV16105S-50T 参数 Datasheet PDF下载

IC41LV16105S-50T图片预览
型号: IC41LV16105S-50T
PDF下载: 下载PDF文件 查看货源
内容描述: 1M ×16 ( 16兆位)动态RAM具有快速页面模式 [1M x 16 (16-MBIT) DYNAMIC RAM WITH FAST PAGE MODE]
分类和应用: 存储内存集成电路光电二极管动态存储器
文件页数/大小: 18 页 / 199 K
品牌: ICSI [ INTEGRATED CIRCUIT SOLUTION INC ]
 浏览型号IC41LV16105S-50T的Datasheet PDF文件第1页浏览型号IC41LV16105S-50T的Datasheet PDF文件第2页浏览型号IC41LV16105S-50T的Datasheet PDF文件第3页浏览型号IC41LV16105S-50T的Datasheet PDF文件第5页浏览型号IC41LV16105S-50T的Datasheet PDF文件第6页浏览型号IC41LV16105S-50T的Datasheet PDF文件第7页浏览型号IC41LV16105S-50T的Datasheet PDF文件第8页浏览型号IC41LV16105S-50T的Datasheet PDF文件第9页  
IC41C16105S
IC41LV16105S
.unctional Description
The IC41C16105S and IC41LV16105S is a CMOS DRAM
optimized for high-speed bandwidth, low power
applications. During READ or WRITE cycles, each bit is
uniquely addressed through the 10 address bits. These
are entered ten bits (A0-A9) at a time. The row address is
latched by the Row Address Strobe (RAS). The column
address is latched by the Column Address Strobe (CAS).
RAS
is used to latch the first ten bits and
CAS
is used the
latter ten bits.
The ICS41C16105S and IC41LV16105S has two
CAS
controls,
LCAS
and
UCAS.
The
LCAS
and
UCAS
inputs
internally generates a
CAS
signal functioning in an iden-
tical manner to the single
CAS
input on the other 1M x 16
DRAMs. The key difference is that each
CAS
controls its
corresponding I/O tristate logic (in conjunction with
OE
and
WE
and
RAS). LCAS
controls I/O0 through I/O7 and
UCAS
controls I/O8 through I/O15.
The IC41C16105S and IC41LV16105S
CAS
function is
determined by the first
CAS
(LCAS or
UCAS)
transitioning
LOW and the last transitioning back HIGH. The two
CAS
controls give the IS41C16105L and IS41LV16105L both
BYTE READ and BYTE WRITE cycle capabilities.
Write Cycle
A write cycle is initiated by the falling edge of
CAS
and
WE,
whichever occurs last. The input data must be valid at or
before the falling edge of
CAS
or
WE,
whichever occurs
last.
Refresh Cycle
To retain data, 1,024 refresh cycles are required in each
16 ms period. There are two ways to refresh the memory.
1. By clocking each of the 1,024 row addresses (A0
through A9) with
RAS
at least once every 16 ms. Any
read, write, read-modify-write or
RAS-only
cycle re-
freshes the addressed row.
2. Using a
CAS-before-RAS
refresh cycle.
CAS-before-
RAS
refresh is activated by the falling edge of
RAS,
while holding
CAS
LOW. In
CAS-before-RAS
refresh
cycle, an internal 10-bit counter provides the row
addresses and the external address inputs are ignored.
CAS-before-RAS
is a refresh-only mode and no data
access or device selection is allowed. Thus, the output
remains in the High-Z state during the cycle.
Self Refresh Cycle
The Self Refresh allows the user a dynamic refresh, data
retention mode at the extended refresh period of 128 ms.
i.e., 125 µs per row when using distributed CBR refreshes.
The feature also allows the user the choice of a fully static,
low power data retention mode. The optional Self Refresh
feature is initiated by performing a CBR Refresh cycle and
holding
RAS
LOW for the specified t
RAS
.
The Self Refresh mode is terminated by driving
RAS
HIGH
for a minimum time of t
RP
. This delay allows for the
completion of any internal refresh cycles that may be in
process at the time of the
RAS
LOW-to-HIGH transition. If
the DRAM controller uses a distributed refresh sequence,
a burst refresh is not required upon exiting Self Refresh.
However, if the DRAM controller utilizes a
RAS-only
or
burst refresh sequence, all 1,024 rows must be refreshed
within the average internal refresh rate, prior to the re-
sumption of normal operation.
Memory Cycle
A memory cycle is initiated by bring
RAS
LOW and it is
terminated by returning both
RAS
and
CAS
HIGH. To
ensures proper device operation and data integrity any
memory cycle, once initiated, must not be ended or
aborted before the minimum t
RAS
time has expired. A new
cycle must not be initiated until the minimum precharge
time t
RP
, t
CP
has elapsed.
Read Cycle
A read cycle is initiated by the falling edge of
CAS
or
OE,
whichever occurs last, while holding
WE
HIGH. The
column address must be held for a minimum time specified
by t
AR
. Data Out becomes valid only when t
RAC
, t
AA
, t
CAC
and t
OEA
are all satisfied. As a result, the access time is
dependent on the timing relationships between these
parameters.
Power-On
After application of the V
CC
supply, an initial pause of
200 µs is required followed by a minimum of eight initial-
ization cycles (any combination of cycles containing a
RAS
signal).
During power-on, it is recommended that
RAS
track with
V
CC
or be held at a valid V
IH
to avoid current surges.
4
Integrated Circuit Solution Inc.
DR011-0A 05/23/2001