IC63LV1024
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
–40°C to +85°C
V
CC
3.3V
±
0.3V
3.3V
±
0.3V
DC ELECTRICAL CHARACTERISTICS
(Over Operating Range)
Symbol Parameter
V
OH
V
OL
V
IH
V
IL
I
LI
I
LO
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
(1)
Input Leakage
Output Leakage
GND
≤
V
IN
≤
V
CC
GND
≤
V
OUT
≤
V
CC
, Outputs Disabled
Com.
Ind.
Com.
Ind.
Test Conditions
V
CC
= Min., I
OH
= –4.0 mA
V
CC
= Min., I
OL
= 8.0 mA
Min.
2.4
—
2.2
–0.3
–2
–5
–2
–5
Max.
—
0.4
V
CC
+ 0.3
0.8
2
5
2
5
Unit
V
V
V
V
µA
µA
Notes:
1. V
IL
= –3.0V for pulse width less than 10 ns.
2. The Vcc operating range for 8 ns is 3.3V +10%, -5%.
POWER SUPPLY CHARACTERISTICS
(1)
(Over Operating Range)
Symbol Parameter
I
CC
1
I
SB
1
Vcc Operating
Supply Current
TTL Standby
Current
(TTL Inputs)
CMOS Standby
Current
(CMOS Inputs)
Test Conditions
V
CC
= Max.,
CE
= V
IL
I
OUT
= 0 mA, f = Max.
V
CC
= Max.,
V
IN
= V
IH
or V
IL
CE
≥
V
IH
, f = 0
V
CC
= Max.,
CE
≤
V
CC
– 0.2V,
V
IN
≥
V
CC
– 0.2V, or
V
IN
≤
0.2V, f = 0
Com.
Ind.
Com.
Ind.
Com.
Ind.
-8 ns
Min.
Max.
—
—
—
—
—
—
160
170
30
40
10
15
-10 ns
Min.
Max.
—
—
—
—
—
—
150
160
30
40
10
15
-12 ns
Min.
Max.
—
—
—
—
—
—
140
150
30
40
10
15
-15 ns
Min.
Max. Unit
—
—
—
—
—
—
130
140
30
40
10
15
mA
mA
I
SB
2
mA
Notes:
1. At f = f
MAX
, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE
(1,2)
Symbol
C
IN
C
I/O
Parameter
Input Capacitance
Input/Output Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Max.
6
8
Unit
pF
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: T
A
= 25°C, f = 1 MHz, Vcc = 3.3V.
Integrated Circuit Solution Inc.
AHSR025-0D
04/16/2004
5