IS61LV6416
ABSOLUTE MAXIMUM RATINGS
(1)
Symbol
V
TERM
T
STG
P
T
I
OUT
Parameter
Terminal Voltage with Respect to GND
Storage Temperature
Power Dissipation
DC Output Current (LOW)
Value
0.5 to Vcc+0.5
65 to +150
1.5
20
Unit
V
°C
W
mA
Note:
1. Stress greater than those listed under
ABSOLUTE MAXIMUM RATINGS may
cause permanent damage to the
device. This is a stress rating only and
functional operation of the device at
these or any other conditions above
those indicated in the operational sec-
tions of this specification is not implied.
Exposure to absolute maximum rating
conditions for extended periods may
affect reliability.
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
40°C to +85°C
Vcc
3.3V ± 10%
3.3V ± 10%
!
"
Min.
2.4
2
0.3
Max.
0.4
V
CC
+ 0.3
0.8
2
5
2
5
Unit
V
V
V
V
µA
µA
DC ELECTRICAL CHARACTERISTICS
(Over Operating Range)
Symbol
V
OH
V
OL
V
IH
V
IL
I
LI
I
LO
Parameter
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
(1)
Input Leakage
Output Leakage
GND
≤
V
IN
≤
V
CC
GND
≤
V
OUT
≤
V
CC
, Outputs Disabled
Com.
Ind.
Com.
Ind.
Test Conditions
V
CC
= Min., I
OH
= 4.0 mA
V
CC
= Min., I
OL
= 8.0 mA
#
$
%
&
'
2
-5
2
-5
Notes:
1. V
IL
(min.) = 2.0V for pulse width less than 10 ns.
2. The Vcc operating range for 8 ns is 3.3V +10%, -5%.
POWER SUPPLY CHARACTERISTICS
(1)
(Over Operating Range)
Symbol
I
CC
I
SB
Parameter
Vcc Dynamic Operating
Supply Current
TTL Standby Current
(TTL Inputs)
CMOS Standby
Current (CMOS Inputs)
Test Conditions
V
CC
= Max.,
I
OUT
= 0 mA, f = f
MAX
V
CC
= Max.,
V
IN
= V
IH
or V
IL
CE
≥
V
IH
, f = 0
V
CC
= Max.,
CE
≥
V
CC
0.2V,
V
IN
≥
V
CC
0.2V, or
V
IN
≤
0.2V, f = 0
Com.
Ind.
Com.
Ind.
Com.
Ind.
-8 ns
Min. Max.
220
230
30
40
10
15
-10 ns
Min. Max.
200
210
30
40
10
15
-12 ns
Min. Max.
180
190
30
40
10
15
-15 ns
Min. Max.
180
190
30
40
10
15
Unit
mA
mA
3
I
SB
mA
Note:
1. At f = f
MAX
, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
Integrated Circuit Solution Inc.
SR013-0C