 浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第30页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第31页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第32页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第33页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第35页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第36页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第37页浏览型号MT48H16M32LFCM-75L的Datasheet PDF文件第38页  
512Mb: 32 Meg x 16, 16 Meg x 32 Mobile SDRAM
Operations
Fixed-length WRITE bursts can be truncated with the BURST TERMINATE command.
When truncating a WRITE burst, the input data applied coincident with the BURST
TERMINATE command will be ignored. The last data written (provided that DQM is
LOW at that time) will be the input data applied one clock previous to the BURST
TERMINATE command. This is shown in Figure 24 on page 33, where data
n
is the last
desired data element of a longer burst.
PRECHARGE
The PRECHARGE command (see Figure 25 on page 34) is used to deactivate the open
row in a particular bank or the open row in all banks. The bank(s) will be available for a
subsequent row access some specified time (
t
RP) after the precharge command is
issued. Input A10 determines whether one or all banks are to be precharged, and in the
case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all
banks are to be precharged, inputs BA0, BA1 are treated as “Don’t Care.” Once a bank
has been precharged, it is in the idle state and must be activated prior to any READ or
WRITE commands being issued to that bank.
Figure 25:
PRECHARGE Command
CLK
CKE
CS#
HIGH
RAS#
CAS#
WE#
A0–A9, A11, A12
All Banks
A10
Bank Selected
BA0,1
BANK
ADDRESS
VALID ADDRESS
DON’T CARE
Power-Down
Power-down occurs if CKE is registered LOW coincident with a NOP or COMMAND
INHIBIT when no accesses are in progress. If power-down occurs when all banks are
idle, this mode is referred to as precharge power-down; if power-down occurs when
there is a row active in any bank, this mode is referred to as active power-down. Entering
power-down deactivates the input and output buffers, excluding CKE, for maximum
power savings while in standby. The device may not remain in the power-down state
longer than the refresh period (64ms) since no REFRESH operations are performed in
this mode.