欢迎访问ic37.com |
会员登录 免费注册
发布采购

PDSP16330 参数 Datasheet PDF下载

PDSP16330图片预览
型号: PDSP16330
PDF下载: 下载PDF文件 查看货源
内容描述: 毕达哥拉斯处理器 [Pythagoras Processor]
分类和应用:
文件页数/大小: 9 页 / 176 K
品牌: MITEL [ MITEL NETWORKS CORPORATION ]
 浏览型号PDSP16330的Datasheet PDF文件第1页浏览型号PDSP16330的Datasheet PDF文件第3页浏览型号PDSP16330的Datasheet PDF文件第4页浏览型号PDSP16330的Datasheet PDF文件第5页浏览型号PDSP16330的Datasheet PDF文件第6页浏览型号PDSP16330的Datasheet PDF文件第7页浏览型号PDSP16330的Datasheet PDF文件第8页浏览型号PDSP16330的Datasheet PDF文件第9页  
PDSP16330/A/B
X15:0
Y15:0
CEX
CEY
16
16
SIGN
SIGN
16
FORM
MAGNITUDE
15
2
X
30
MAGNITUDE
15
2
Y
30
SIGN X
SIGN Y
X>Y
Y/X
9
π
/4
ARCTAN
ROM
9
+
32
2
2
X +Y
16
S0
ROTATE
12
SHIFT
S1
2
OEM
OEP
M15:0
OVR
P11:0
Fig.2 Block diagram
FUNCTIONAL DESCRIPTION
The PDSP16330 converts incoming Cartesian Data
into the equivalent Polar Values. The device accepts new 16
+ 16 bit complex data every cycle, and delivers a 16 bit + 12
bit Polar equivalent after 24 clock cycles.The input data can be
in 2s’ Complement or Sign Magnitude format selected via the
FORM input. The output is in a magnitude format for both the
Magnitude output and the Phase. Phase data is zero for data
with a zero Y input and positive X, and is 400 hex for zero X
data and positive Y, is 800 hex for zero Y data and negative X,
and is C00 hex for zero X and negative Y. The LSB weighting
(bit 0) is 2 x
π/4096
radians. The 16 bit Magnitude result may
be scaled by shifting one, two, or three places in the more
significant direction, effectively multiplying the Magnitude
result by 2,4 or 8 respectively. Any of these shifts can under
certain conditions cause an invalid result to be output from the
device. Under these circumstances the OVR output will
become active. The PDSP16330 has independent clock
enables and three state output controls for all ports.
S1-0
These inputs select the scaling factor to be applied to
the Magnitude output. They are latched by the rising edge of
CLK and determine the scaling of the output in the cycle after
they are loaded into the device. The scale factor applied is
determined by the table. Should the scaling factor applied
cause an invalid Magnitude result to be output on the M Port,
then the OVR Flag will become active for the period that the
M Port output is invalid.
S1
0
0
1
1
S0
0
1
0
1
Scaling Factor
x1
x2
x4
x8
FORM
This input selects the format of the X and Y input data.
A low level on FORM indlcates that the Input data is twos’
complement format (Note: input data 8000 hex is not valid in
2s’ complement mode). This input refers to the format of the
current Input data and may be changed on a per cycle basis
if desired. The level of FORM is latched at the same time as
the data to which it refers.
The output number range is from 0 to 2 when the
scaling factor is set at x1.
2