 浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第3页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第4页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第5页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第6页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第8页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第9页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第10页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第11页  
OKX
T/10 & T/16-D12 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
In the figure, the two copper strips simulate real-world printed circuit
impedances between the power supply and its load. In order to minimize circuit
errors and standardize tests between units, scope measurements should be
made using BNC connectors or the probe ground should not exceed one half
inch and soldered directly to the fixture.
Minimum Output Loading Requirements
All models regulate within specification and are stable under no load to full
load conditions. Operation under no load might however slightly increase
output ripple and noise.
Thermal Shutdown
To prevent many over temperature problems and damage, these converters
include thermal shutdown circuitry. If environmental conditions cause the
temperature of the DC/DC’s to rise above the Operating Temperature Range
up to the shutdown temperature, an on-board electronic temperature sensor
will power down the unit. When the temperature decreases below the turn-on
threshold, the converter will automatically restart. There is a small amount of
temperature hysteresis to prevent rapid on/off cycling. The temperature sensor
is typically located adjacent to the switching controller, approximately in the
center of the unit. See the Performance and Functional Specifications.
CAUTION:
If you operate too close to the thermal limits, the converter may
shut down suddenly without warning. Be sure to thoroughly test your applica-
tion to avoid unplanned thermal shutdown.
Temperature Derating Curves
The graphs in the next section illustrate typical operation under a variety of
conditions. The Derating curves show the maximum continuous ambient air
temperature and decreasing maximum output current which is acceptable
under increasing forced airflow measured in Linear Feet per Minute (“LFM”).
Note that these are AVERAGE measurements. The converter will accept brief
increases in current or reduced airflow as long as the average is not exceeded.
Note that the temperatures are of the ambient airflow, not the converter
itself which is obviously running at higher temperature than the outside air.
Also note that very low flow rates (below about 25 LFM) are similar to “natural
convection”, that is, not using fan-forced airflow.
Murata Power Solutions makes Characterization measurements in a closed
cycle wind tunnel with calibrated airflow. We use both thermocouples and an
infrared camera system to observe thermal performance.
CAUTION:
If you routinely or accidentally exceed these Derating guidelines,
the converter may have an unplanned Over Temperature shut down. Also, these
graphs are all collected at slightly above Sea Level altitude. Be sure to reduce
the derating for higher density altitude.
Output Overvoltage Protection
This converter monitors its output voltage for an over-voltage condition. If
the output exceeds OVP limits, the sensing circuit will power down the unit,
and the output voltage will decrease. After a time-out period, the PWM will
automatically attempt to restart, causing the output voltage to ramp up to its
rated value. It is not necessary to power down and reset the converter for the
automatic OVP-recovery restart.
If the fault condition persists and the output voltage climbs to excessive
levels, the OVP circuitry will initiate another shutdown cycle. This on/off cycling
is referred to as “hiccup” mode. It safely tests full current rated output voltage
without damaging the converter.
Output Fusing
The converter is extensively protected against current, voltage and temperature
extremes. However your output application circuit may need additional protec-
tion. In the extremely unlikely event of output circuit failure, excessive voltage
could be applied to your circuit. Consider using an appropriate fuse in series
with the output.
Output Current Limiting
As soon as the output current increases to approximately 125% to 150% of
its maximum rated value, the DC/DC converter will enter a current-limiting
mode. The output voltage will decrease proportionally with increases in output
current, thereby maintaining a somewhat constant power output. This is also
commonly referred to as power limiting.
Current limiting inception is defined as the point at which full power falls
below the rated tolerance. See the Performance/Functional Specifications.
Note particularly that the output current may briefly rise above its rated value
in normal operation as long as the average output power is not exceeded. This
enhances reliability and continued operation of your application. If the output
current is too high, the converter will enter the short circuit condition.
Output Short Circuit Condition
When a converter is in current-limit mode, the output voltage will drop as the
output current demand increases. If the output voltage drops too low (approxi-
mately 98% of nominal output voltage for most models), the PWM controller
will shut down. Following a time-out period, the PWM will restart, causing the
output voltage to begin ramping up to its appropriate value. If the short-circuit
condition persists, another shutdown cycle will initiate. This rapid on/off cycling
is called “hiccup mode”. The hiccup cycling reduces the average output cur-
rent, thereby preventing excessive internal temperatures and/or component
damage. A short circuit can be tolerated indefinitely.
Remote Sense Input
The Sense input is normally connected at the load for the respective Sense
polarity (+Sense to the +Vout load). Sense inputs compensate for voltage drops
along the output wiring such as moderate IR drops and the current carrying
capacity of PC board etch. This output drop (the difference between Sense and
Vout when measured at the converter) should not exceed 0.5V. Use heavier
connections if this drop is excessive. Sense inputs also improve the stability of
the converter and load system by optimizing the control loop phase margin.
If the Sense function is not used for remote regulation, the user should con-
nect the Sense to their respective Vout at the converter pins.
Sense lines on the PCB should run adjacent to DC signals, preferably
Ground. Any long, distributed wiring and/or significant inductance introduced
into the Sense control loop can adversely affect overall system stability. If in
doubt, test your applications by observing the converter’s output transient
response during step loads. There should not be any appreciable ringing or
oscillation.
You may also adjust the output trim slightly to compensate for voltage loss
in any external filter elements. Do not exceed maximum power ratings. Exces-
sive voltage differences between Vout and Sense together with trim adjustment