欢迎访问ic37.com |
会员登录 免费注册
发布采购

OKX2-T/16-D12N-C 参数 Datasheet PDF下载

OKX2-T/16-D12N-C图片预览
型号: OKX2-T/16-D12N-C
PDF下载: 下载PDF文件 查看货源
内容描述: 可调DOSA 10/16放大器SIP DC / DC转换器 [Adjustable DOSA 10/16-Amp SIP DC/DC Converters]
分类和应用: 转换器放大器
文件页数/大小: 15 页 / 518 K
品牌: MURATA-PS [ MURATA POWER SOLUTIONS INC. ]
 浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第1页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第2页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第3页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第5页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第6页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第7页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第8页浏览型号OKX2-T/16-D12N-C的Datasheet PDF文件第9页  
OKX
T/10 & T/16-D12 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Specification Notes, Cont.:
(7)
“Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output.
If the overcurrent condition still exists, the restart current will be removed and then tried again. This short
current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter
immediately recovers normal operation.
Output noise may be further reduced by adding an external filter. At zero output current, the output may
contain low frequency components which exceed the ripple specification. The output may be operated
indefinitely with no load.
All models are fully operational and meet published specifications, including “cold start” at –40°C.
OKX2-T/10-D12, -T/16-D12
Output Voltage
5.0 V.
3.3 V.
2.5 V.
2.0 V.
1.8 V.
1.5 V.
1.2 V.
1.0 V.
0.7525 V.
Calculated Rtrim (KΩ)
1.472
3.122
5.009
7.416
9.024
13.05
22.46
41.424
∞ (open)
(8)
(9)
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied
from a nominal midpoint value to either extreme.
(11) Other input or output voltage ranges will be reviewed under scheduled quantity special order.
(12) Maximum PC board temperature is measured with the sensor in the center of the converter.
(13) Do not exceed maximum power specifications when adjusting the output trim.
(14) The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external
output capacitor and, to a lesser extent, the distance and series impedance to the load. Larger caps will
reduce output noise but may change the transient response. Newer ceramic caps with very low ESR may
require lower capacitor values to avoid instability. Thoroughly test your capacitors in the application. Please
refer to the Output Capacitive Load Application Note.
(15) Do not allow the input voltage to degrade lower than the input undervoltage shutdown voltage at all times.
Otherwise, you risk having the converter turn off. The undervoltage shutdown is not latching and will
attempt to recover when the input is brought back into normal operating range.
(16) The outputs are not intended to sink appreciable reverse current.
Resistor Trim Equation, D12 models:
10500
R
TRIM
(Ω) = ________________ –1000
V
OUT
– 0.7525V
Output Voltage Adjustment
The output voltage may be adjusted over a limited range by connect-
ing an external trim resistor (Rtrim) between the Trim pin and Ground. The
Rtrim resistor must be a 1/10 Watt precision metal film type, ±1% accuracy
or better with low temperature coefficient, ±100 ppm/°C. or better. Mount
the resistor close to the converter with very short leads or use a surface
mount trim resistor.
In the tables opposite, the calculated resistance is given. Do not exceed
the specified limits of the output voltage or the converter’s maximum power
rating when applying these resistors. Also, avoid high noise at the Trim
input. However, to prevent instability, you should never connect any capaci-
tors to Trim.
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifica-
tions may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production
environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
115° C.
270° C.
7 seconds
For Sn/Pb based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
105° C.
250° C.
6 seconds
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_MDC_OKX2_T10T16.A03
Page 4 of 15