5041 series
ELECTRICAL CHARACTERISTICS
DC Characteristics (5041A1
×
to A6
×
)
V
DD
=
2.25V to 3.63V, V
SS
=
0V, Ta
= −40°C
to
+85°C,
C
LOUT
= 15pF unless otherwise noted.
Rating
Parameter
Symbol
Conditions
MIN
5041A1× (f
OUT
= fo),
Measurement circuit 1, no load,
INHN
=
HIGH, fo
=
48MHz
5041A2× (f
OUT
= fo/2),
Measurement circuit 1, no load,
INHN
=
HIGH, fo
=
48MHz
5041A3× (f
OUT
= fo/4),
Measurement circuit 1, no load,
INHN
=
HIGH, fo
=
48MHz
5041A4× (f
OUT
= fo/8),
Measurement circuit 1, no load,
INHN
=
HIGH, fo
=
48MHz
5041A5× (f
OUT
= fo/16),
Measurement circuit 1, no load,
INHN
=
HIGH, fo
=
48MHz
5041A6× (f
OUT
= fo/32),
Measurement circuit 1, no load,
INHN
=
HIGH, fo
=
48MHz
Standby-mode current
consumption
HIGH-level output voltage
LOW-level output voltage
Output leakage current
HIGH-level input current
LOW-level input current
INHN pull-up resistance
I
ST
V
OH
V
OL
I
Z
V
IH
V
IL
R
PU1
R
PU2
Measurement circuit 6
INHN
=
V
SS
INHN
=
0.7V
DD
V
DD
=
2.5V
V
DD
=
3.3V
V
DD
=
2.5V
V
DD
=
3.3V
V
DD
=
2.5V
V
DD
=
3.3V
V
DD
=
2.5V
V
DD
=
3.3V
V
DD
=
2.5V
V
DD
=
3.3V
V
DD
=
2.5V
V
DD
=
3.3V
–
–
–
–
–
–
–
–
–
–
–
–
–
V
DD
−0.4
–
–
−10
0.7V
DD
–
0.4
50
TYP
1.4
1.7
1.1
1.4
1.0
1.2
0.9
1.0
0.8
1.0
0.8
1.0
–
–
–
–
–
–
–
1.5
100
MAX
2.8
3.4
2.2
2.7
1.9
2.4
1.7
2.1
1.7
2.0
1.6
2.0
10
–
0.4
10
–
–
0.3V
DD
10
200
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
µA
V
V
µA
µA
V
V
MΩ
kΩ
Unit
Operating-mode current
consumption
*1
I
DD
Measurement circuit 1, INHN
=
LOW
Q pin, Measurement circuit 3, I
OH
=
−4mA
Q pin, Measurement circuit 3, I
OL
=
4mA
Measurement circuit 4,
INHN
=
LOW
INHN pin, Measurement circuit 5
Q
=
V
DD
Q
=
V
SS
*1. The consumption current I
DD
(C
LOUT
) with a load capacitance (C
LOUT
) connected to the Q pin is given by the following equation, where I
DD
is the no-
load consumption current and f
OUT
is the output frequency.
I
DD
(C
LOUT
) [mA] = I
DD
[mA] + C
LOUT
[pF]
×
V
DD
[V]
×
f
OUT
[MHz]
×
10
–3
SEIKO NPC CORPORATION—5