M25PE40
Table 17.
Symbol
I
LI
I
LO
I
CC1
I
CC2
I
CC3
I
CC4
I
CC5
V
IL
V
IH
V
OL
V
OH
DC and AC parameters
DC characteristics
Parameter
Input Leakage current
Output Leakage current
Standby current
(Standby and Reset modes)
Deep Power-down current
Operating current
(FAST_READ)
Operating current (PW)
Operating current (SE)
Input Low voltage
Input High voltage
Output Low voltage
Output High voltage
I
OL
= 1.6 mA
I
OH
= –100 µA
V
CC
–0.2
S = V
CC
, V
IN
= V
SS
or V
CC
S = V
CC
, V
IN
= V
SS
or V
CC
C = 0.1V
CC
/0.9.V
CC
at 25 MHz, Q = open
C = 0.1V
CC
/0.9.V
CC
at 50 MHz, Q = open
S = V
CC
S = V
CC
– 0.5
0.7V
CC
Test condition
(in addition to those in
Min.
Max.
±2
±2
50
10
6
8
15
15
0.3V
CC
V
CC
+0.4
0.4
Unit
µA
µA
µA
µA
mA
mA
mA
mA
V
V
V
V
Table 18.
Symbol
I
LI
I
LO
I
CC1
I
CC2
I
CC3
I
CC4
I
CC5
V
IL
V
IH
V
OL
V
OH
DC characteristics (75 MHz operation, T9HX (0.11
µm) process)
(1)
Parameter
Input Leakage current
Output Leakage current
Standby current
(Standby and Reset modes)
Deep Power-down current
Operating current
(FAST_READ)
Operating current (PW)
Operating current (SE)
Input Low voltage
Input High voltage
Output Low voltage
Output High voltage
I
OL
= 1.6 mA
I
OH
= –100 µA
V
CC
–0.2
S = V
CC
, V
IN
= V
SS
or V
CC
S = V
CC
, V
IN
= V
SS
or V
CC
C = 0.1V
CC
/0.9.V
CC
at 33 MHz, Q = open
C = 0.1V
CC
/0.9.V
CC
at 75 MHz, Q = open
S = V
CC
S = V
CC
– 0.5
0.7V
CC
Test condition
(in addition to those in
Min.
Max.
±2
±2
50
10
4
12
15
15
0.3V
CC
V
CC
+0.4
0.4
Unit
µA
µA
µA
µA
mA
mA
mA
mA
V
V
V
V
1. Delivery of parts operating with a maximum clock rate of 75 MHz starts from week 8 of 2008.
47/62