Analog Frequency Multiplier
PL560-xx VCXO Family
ELECTRICAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
PARAMETERS
Supply Voltage
Input Voltage, DC
Output Voltage, DC
Storage Temperature
Ambient Operating Temperature, Industrial Temperature
Ambient Operating Temperature, Commercial Temperature
Junction Temperature
Lead Temperature (soldering, 10s)
Input Static Discharge Voltage Protection
SYMBOL
V
DD
V
I
V
O
T
S
T
A_I
T
A_C
T
J
MIN.
MAX.
4.6
UNITS
V
V
V
°C
°C
°C
°C
°C
kV
GND-0.5
GND-0.5
-65
-40
0
V
DD
+0.5
V
DD
+0.5
150
+85
+70
125
260
2
Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent
damage to the device and affect product reliability. These conditions represent a stress rating only, and functional operations of the
device at these or any other conditions above the operational limits noted in this specification is not implied.
PECL ELECTRICAL CHARACTERISTICS
PARAMETERS
Supply Current (with loaded outputs)
Operating Voltage
Output Clock Duty Cycle
Short Circuit Current
Output High Voltage
Output Low Voltage
Clock Rise Time
Clock Fall Time
V
OH
V
OL
t
r
t
f
@20/80%
@80/20%
0.25
0.25
R
L
= 50
Ω
to
(V
DD
– 2V)
V
DD
– 1.025
V
DD
– 1.620
0.45
0.45
SYMBOL
I
DD
V
DD
CONDITIONS
Fout = 622 MHz
MIN.
2.25
TYP.
75
MAX.
80
3.63
55
UNITS
mA
V
%
mA
V
V
ns
ns
@ Vdd – 1.3V
45
50
±50
PECL Transition Time Waveform
DUTY CYCLE
PECL Levels Test Circuit
OUT
VDD
OUT
PECL Output Skew
45 - 55%
55 - 45%
OUT
50Ω
2.0V
50%
80%
20%
50Ω
OUT
OUT
t
SKEW
OUT
t
R
t
F
47745 Fremont Blvd., Fremont, CA 94538 TEL (510) 492-0990, FAX (510) 492-0991
Rev.:02-09-07 Page 9