MAP110 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
CURRENT (NOTE 1)
FORCED AIR
CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
+5V
+12V
-5V
-12V
+5V
+12V
-12V
+24V
+5V
+12V
-15V
+15V
+12V
+24V
-12V
+5V
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
11.55V to 12.45V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
0.2%
0.1%
0.2%
0.3%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.3%
0.2%
0.1%
0.1%
0.3%
0.2%
0.1%
0.1%
0.5%
2%
1.5%
8%
0.5%
1%
1%
1%
0.5%
1%
1%
1%
0.5%
1%
1%
1.5%
0.7%
1%
1%
1%
0.7%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.03V
-4.75V to -5.25V
-11.5V to -12.5V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
23.2V to 24.8V
5.09V to 5.11V
11.97V to 12.03V
-14.4V to -15.6V
14.4V to 15.6V
11.96V to 12.03V
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
MAP110-4010
MAP110-4011
MAP110-4015
MAP110-4200
1A/1.5A PK
1A/1.5A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
+3.3V
+5V
-12V
+12V
+3.3V
+5V
MAP110-4300
(Note 3)
MAP110-4305
-5V
+12V
Fixed
Fixed
(Note 3)
1%
NOTES: 1) Peak loads up to 110 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 Watts.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Sum of the output currents of V1 + V2 may not exceed 15A continuous, 22A peak.
MAXIMUM OUTPUT RATING:
MODEL/OUTPUT
OPTION
MULTIPLE OUTPUT
BOARD ONLY
SINGLE OUTPUT
BOARD ONLY
MULTIPLE OUTPUT
‘L’-BRACKET
SINGLE OUTPUT
‘L’-BRACKET
MULTIPLE OUTPUT
‘C’-COVER
SINGLE OUTPUT
C’-COVER
65W/120W
120W
CONVECTION
CONTINUOUS/PEAK
80W/110W
110W
90W/120W
120W
80W/110W
110W
90W/120W
120W
60W/110W
110W
FORCED AIR
200 LFM
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
85
47
85
40
20
NOM
MAX
UNITS
VAC
Hz
VAC
mS
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
264
63
Nominal AC input voltage (110 VAC)
50% load:
Full rated load:
Input Current
85 VAC (110W load).
110VAC (110W load).
3.5
2.8
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25°C.
41
25
APK
kHz
Operating Frequency
Switching frequency of main transformer, (fixed frequency).
20
2