MAP110 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load, 230 VAC. Varies with distribution of loads among outputs.
65
75
80
%
Minimum Loads
Single output models.
Multiple output models, V1 + V2 (Note 1).
0
1
Amps
Amps
Ripple and Noise
Output Power
Full Load, 20 MHz Bandwidth.
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
See Model Selection Chart.
5
5
80
Watts
Watts
110
Overshoot / Undershoot
Regulation
Output voltage overshoot/undershoot at turn-on.
0
V
Varies by output, regulation includes: line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
See Model Selection Chart.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
500
µS
Sec
mS
Turn-on Delay
Turn-on Rise Time
1
20
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on single output models and the
main output of multiple output models.
MAP110-1005
MAP110-1012
MAP110-1024
MAP110-4200
MAP110-4300
All other models.
6.10
17.3
32.2
13.8
3.7
7.20
20.2
37.8
16.2
4.35
6.75
V
5.75
Overload Protection
Remote Sense
Input Power Fail
Warning
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 110 VAC. Active low.
150
5
200
%
250
mV
mS
3
Overtemperature Protection
Option, system shutdown due to excessive internal temperature.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Approved.
Dielectric Withstand Voltage
Input to Output.
2600
VDC
Electromagnetic
Interference,
Conducted
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated (Note 2).
B
B
A
Class
Input Transient Protection
Insulation Resistance
Leakage Current
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264 VAC.
2
10
kV
M⍀
µA
750
NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
3