November 2006
rev 1.5
Operating Conditions for ASM5I23S08A Industrial Temperature Devices
Parameter
V
DD
T
A
C
L
C
L
C
IN
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance, below 100MHz
Load Capacitance, from 100MHz to 133MHz
Input Capacitance
ASM5P23S08A
Description
Min
3.0
-40
Max
3.6
85
30
15
7
Unit
V
°C
pF
pF
pF
Electrical Characteristics for ASM5I23S08A Industrial Temperature Devices
Parameter
V
IL
V
IH
I
IL
I
IH
V
OL
Description
Input LOW Voltage
Input HIGH Voltage
Input LOW Current
Input HIGH Current
Output LOW Voltage
V
IN
= 0V
V
IN
= V
DD
Test Conditions
Min
Max
0.8
Unit
V
V
2.0
50.0
100.0
0.4
µA
µA
V
I
OL
= 8mA ( -2)
I
OH
= 12mA ( -5H)
I
OL
= -8mA ( -2)
I
OH
= -12mA ( -5H)
Unloaded outputs 100MHz REF,
Select inputs at V
DD
or GND
(-2,-3,-4)
(-1H,-5H)
(-1, -2, -3, -4)
(-1, -2, -3, -4)
2.4
V
OH
Output HIGH Voltage
V
49
60
mA
34
18
I
DD
Supply Current
10
Unloaded outputs, 66MHz REF
Unloaded outputs, 33MHz REF
Note
10. Supply Currents are measured for PLL-Bypass Mode (S2=1, S1=0)
3.3V ‘SpreadTrak’ Zero Delay Buffer
Notice: The information in this document is subject to change without notice.
8 of 17