1000W Single Output Power Supply
RSP-1000
series
2.Remote ON/OFF
The PSU can be turned ON/OFF by using the "Remote
ON/OFF" function
Between ON/OFF(pin6) and -S(pin2)
SW ON (Short)
SW OFF (Open)
Output Status
ON
OFF
+V
1 11
2 12
-V SVR51 CN50
TB1
1
CN50
AUXG DC_OK
CS
Vci
Vca
11
GND
GND
12
LOAD
+
-
Fig 2.1
+S
-S
2
AUX ON/OFF Vco
SW
3.DC_OK signal
"DC_OK" is an open collector signal.
It indicates the output status of the PSU. It can operate
in two ways : One is sinking current from external TTL
signal ; the other is sending out a TTL voltage signal.
3-1 Sink current :
The maximum sink current is 10mA and the maximum
external voltage is 5.6V.
3-2 TTL voltage signal :
Between DC- OK(pin5) and GND(pin11&12)
0 ~ 1V
3.3 ~ 5.6V
Output Status
ON
OFF
CN50
AUXG DC_OK
CS
Vci
Vca
+V
1 11
2 12
-V SVR51 CN50
TB1
Fig 3.1
1
+S
-S
2
11
GND
GND
12
AUX ON/OFF Vco
4.Remote Sense
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
+V
1 11
2 12
-V SVR51 CN50
TB1
1
Sense lines should
be twisted in pairs
+S
-S
2
CN50
AUXG DC_OK
CS
Vci
Vca
11
GND
GND
12
+S
(pin1)
LOAD
+
-S
- (pin2)
AUX ON/OFF Vco
Fig 4.1
File Name:RSP-1000-SPEC 2006-11-21
ELECTRONIC COMPONENTS
RSG
■
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
■
■
■
■
■
Änderungen vorbehalten / subject to change without notice