BATTERY PROTECTION IC FOR 1-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION)
Rev.3.3
_00
S-8244 Series
(7)
Test Condition 7, Test Circuit 4
Conditions:
•
Set switch 1 to OFF and switch 2 to ON.
Definitions:
•
Set V1, V2, V3 and V4 to 4.6 V and gradually decrease V6 from V
CC
(for CMOS output active “H”
models).
V6 voltage is defined as V
CO (H)
when I2 (= -10
µA)
flows.
•
Set V1, V2, V3 and V4 to 3.5 V and gradually decrease V6 from V
CC
(for CMOS output active “L” or
Pch open drain models).
V6 voltage is defined as V
CO (H)
when I2 (= -10
µA)
flows.
•
Set V1, V2, V3 and V4 to 4.6 V and gradually increase V6 from 0 V (for CMOS output active “L”
models).
V6 voltage is defined as V
CO (L)
when I2 (= 10
µA)
flows.
•
Set V1, V2, V3 and V4 to 3.5 V and gradually increase V6 from 0 V (for CMOS output active “H” or
Nch open drain models).
V6 voltage is defined as V
CO (L)
when I2 (= 10
µA)
flows.
10 MΩ
S-8244
VCC
SENSE
CO
ICT
VSS
VC3
SW1
VCC
10 MΩ
S-8244
CO
ICT
VSS
VC3
SW1
SW2
V
V4
10 MΩ
V1
VC1
SENSE
SW2
0.1
µF
V4
10 MΩ
V
V1
VC1
V2
VC2
V2
VC2
V3
V3
Test Circuit
1
Test Circuit
I1
V5
2
SW1
S-8244
VCC
SENSE
CO
ICT
VSS
VC3
S-8244
VCC
SENSE
CO
ICT
VSS
VC3
SW2
V
V4
I2
V6
I1 V1
V2
V3
I2
I3
VC1
VC2
V1
I4
V4
VC1
V2
VC2
V3
Test Circuit
3
Figure 5
Test Circuit
4
10