Si85xx
Table 1. Electrical Specifications (Continued)
TA = –40 to +85 ºC (typical specified at 25 ºC), VDD = 2.7 to 5.5 V
Parameter
Measurement Error (%)—all devices
(–40 to 125 ºC Temp Range)
Conditions
5 to 10% of full scale
10 to 20% of full scale
20 to 100% of full scale
Min
–30
–25
–20
Typ
—
—
—
Max
+30
+25
+20
Unit
%
%
%
Table 2. Absolute Maximum Ratings
Parameter
Storage temperature
Ambient temperature under bias
Supply voltage
Voltage on any pin with respect to ground
(not including IIN, IOUT)
Lead solder temperature (10 sec.)
DC isolation
Symbol
T
STG
T
A
V
DD
V
IN
-
-
–0.5
Min
–65
–40
Typ
Max
+150
+125
5.75
VDD + 0.5
260
1000
Units
ºC
ºC
V
V
ºC
VDC
Note:
Permanent device damage may occur if the above Absolute Maximum Ratings are exceeded. Functional operation
should be restricted to conditions as specified in the operational sections of this data sheet. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Preliminary Rev. 0.1
5