CINT1275
275W Single Output
Industrial Series
General Specifications
(continued)
Input Fuses
Earth Leakage
Current
Efficiency
F1, F2: 5A, 275Vac fuses provided on all
models
<750μA@264Vac, 60Hz, NC
Overload Protection
Short Circuit
Protection
Overvoltage
Protection
Switching Frequency
120 to 150% of rating, Hiccup Mode
Hiccup Mode, auto recovery.
92% typical
275W continuous, with 200 lfm airflow, 180W
convection cooled – See chart for specific
voltage model ratings.
500µS typical, return to 0.5% of nominal, 50%
load step.
i/t:
<0.2A/μS. Max Voltage
Deviation = 3%
0.5%rms, 1% pk-pk, see chart.
OVP latch at 110 to 130% of output voltage
PFC: Variable, 30kHz - 400kHz
Main Converter: Variable 30-250kHz, 65-
70kHz at full load.
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vac
-10°C to +70°C
Start Up at -40°C, full load
Derate output power linearly above 50°C to
50% at 70°C
Output Power
Transient
Response
Ripple and Noise
Isolation
Operating
Temperature
Temperature
Derating
Storage Temperature
Output Voltage
Voltage
Adjustability
Minimum Load
See chart
+/-5% from nominal (except 56V)
-40°C to +85°C
Not required
Altitude
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
Total Regulation
+/- 3% combined line, load and initial setting.
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall,
3 axes, 1 hr/axis
W: 3.0” x L: 5.0” x H: 1.38” (from bottom of PC
Board).
Relative Humidity
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
Vibration
Shock
Dimensions
Safety Standards
Weight
325g
MTBF
465,000 hours, 275W load, 110Vac input,
25°C ambient
Auxiliary Signals
AC Power Fail:
Goes LOW with 5mS warning before loss of
DC output after loss of AC power.
Connect to inhibit pin (J201 pin 5) to output
common to inhibit the DC output.
Compensates for up to 250mV drop in load
lines.
DC OK:
Open collector logic signal goes and stays HIGH
100mS to 500mS after main output reaches
regulation.
12V @ 1A
Inhibit:
Fan Output:
Remote Sense:
Current Share:
Forced Current Sharing provided for up to 5
units connected in parallel.
www.slpower.com
CINT1275 REV 1.2 15-JAN-13