CINT1275
275W Single Output
Industrial Series
Timing Sequence
Isolation Specifications
Parameter
Insulation Safety Rating
Conditions/Description
Input/Ground
Input/Output
Output/Ground
Input/Ground
Input/Output
Output/Ground
Min
Nom
Basic
Reinforced
n/a
Max
Units
Electric Strength Test Voltage
1800
4000
1500
-
-
Vac
Vac
Vac
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Input Frequency
Inrush Current Limitation
Power Factor
Conditions/Description
Ramping up
Ramping down
Min
90
Nom
115/230
80
75
Max
264
Units
Vac
Vac
Vac
47
264Vac, cold start
Vi
nom,
Io
nom
Vi
nom,
Io
nom
CINT1275A1214K01
CINT1275A1514K01
CINT1275A2414K01
CINT1275A4814K01
CINT1275A5614K01
-
0.9
50/60
-
-
63
50
-
Hz
A
Efficiency
-
92%
-
%
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
5