CINT1275
275W Single Output
Industrial Series
Noise & Ripple
To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with
0.1uF ceramic and a 10uF electrolysis capacitor connected in parallel across it, BW limit with 20MHz.
12V
OUT
, N
O
L
OAD
, 115V
AC
, 60H
Z
12V
OUT
, F
ULL
L
OAD
, 115V
AC
, 60H
Z
12V
OUT
, N
O
L
OAD
, 230V
AC
, 60H
Z
12V
OUT
, F
ULL
L
OAD
, 230V
AC
, 60H
Z
Output Transient Response
50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/μSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY.
12
V OUT
, 115V
AC
, 25%
TO
75% L
OAD
S
TEP
12V
OUT
, 230V
AC
, 25%
TO
75% L
OAD
S
TEP
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
8